63
the illuminator is in
“
Local
”,“
VMS + Local
”
or “
HTTP + Local
”
mode. See page
38 for more information.
My illuminator does not trigger from an external input
–
In standard mode, the
photocell must detect that it is dark (or be disabled) before the illuminator will
respond to an external input. Does your External Input work correctly? Are the
respective telemetry wires (orange and purple) wired correctly? Has the illuminator
been set to trigger from an External input on the illuminators web interface?
My illuminator is not responding to group messages correctly
–
Are all the
illuminators in the same network range with correct IP Addresses and Subnet Masks?
Have all illuminators been assigned to the correct group? Trigger Control must be set
to “
Group Control
”
.
Make sure under the “Respond to Group Commands” is set
to “
Yes, Receive Only
” or “
Yes, Send and Receive
”
. Ensure that if an external
trigger is used then that unit is set to “
Yes, Send and Receive
”.
Ensure that
override function is not running on the illuminators web interface.