39
1. Local
The illuminator will respond ONLY to photocell and telemetry events. The user may
also take direct Manual Override control through the Home Page interface. This is the
default setting.
2. VMS
The illuminator will respond ONLY to third party VMS systems and any applications
that use the Raytec API. The illuminator will NOT respond to photocell and telemetry
events. The user CANNOT take direct manual override control through the web
interface.
3. VMS + Local
The illuminator will respond to third party VMS systems and any applications that use
the Raytec API and the illuminator will ALSO respond to photocell and telemetry
events. The user may ALSO take direct Manual Override control through the home
page of the illuminators web interface.
IMPORTANT:
For detailed instructions on
“
VMS
”
and
“
VMS + Local
”
modes please refer to the Raytec
API Document
.
4. HTTP
The illuminator will respond ONLY to any device / application generating valid HTTP
commands and any applications that use the Raytec HTTP API. The illuminator will
NOT respond to photocell and telemetry events. The user CANNOT take direct
Manual Override control through the web interface.
5. HTTP + Local.
The illuminator will respond to any device / application generating valid HTTP
commands and any applications that use the Raytec HTTP API and the illuminator will
ALSO respond directly to photocell and telemetry events. The user may ALSO take
Содержание VARIO2 IP 16 Series
Страница 3: ...3 has a HTTP API to control the illuminator via HTTP commands...
Страница 4: ...4...
Страница 30: ...30 Unit Name and Group Name can both be edited by entering a new value in their fields...
Страница 60: ...60 Log Off We recommend after using the illuminator web interface that users log off using the Log Off Page...
Страница 64: ...64 Version Vario2 IP 16 Instruction Guide Rev 1 0 0 Full...