8
Interchangeable Lenses: Changing the Angle
The illuminator is delivered with a 35
o
beam angle. To alter to 10
o
, remove the
baseplate from the bottom of the product and remove the existing lens and then re-
attach the baseplate securely. With no lens insert the product produces a 10
o
beam
angle.
To alter to any other angle, remove the existing lens and insert the required lens
which will have its angle indicated on it. Ensure the baseplate is securely re-attached
to maintain waterproof integrity of the product.
The angles available as standard ar
e: 10°x10° (NO lens / diffuser in place), 35°x10°
and 60°x25°. Other angles are available to order: 80°x30° and 120°x50°.
Installation
VARIO2 IP is delivered as standard with a bracket at the bottom of the unit. This
can be moved to the top of the unit if required.
Attach illuminator to wall, housing or pole using U-bracket provided or dedicated
Raytec bracketry.
Step 1
Unscrew baseplate
Step 2
Remove baseplate
Step 3
Remove / Replace
diffuser lens
Step 4
Replace baseplate
& tighten