44
period and it will have the effect of restarting the timer.
The illuminator will stay ON until the end of the timed period even if the illuminators
photocell states it is daylight.
Min and Max timer settings are:
Photocell Min:
30 mins
External Input Min: 1 mins
Photocell Max:
720 mins
External Input Max: 60 mins
Factory Defaults: Photocell
All Night
External Input
Duration of Input
Soft Start
There is the option, when a valid on instruction is received, for the illuminator to
either start immediately
(
Soft Start Off)
or to ramp up to selected power level
(Soft
Start On)
.
The length of time of the ramp up depends on power level selected. (Max 10 seconds
for 100% power)
Factory Defaults: Photocell
On
External Input
Off
Deterrent Pattern & Frequency
There are 3 selectable deterrent patterns available if Deter Feature selected from
Illuminator Mode on Trigger: