39
Display
Condition
H2O Sensor Fail
Water temperature sensors open, shorted, or disagree
Aux Ctrl Fault 2
ROM CRC failure on companion board
Aux Ctrl Fault 3
RAM failure on companion board
Aux Ctrl Fault 5
A/D Reference failure on companion board
Aux Ctrl Fault 6
A/D Multiplexor failure on companion board
Aux Ctrl Fault 8
Unable to read time of day clock
Ign Ctrl Fault 2
ROM CRC failure on Ignition Control
Ign Ctrl Fault 3
RAM failure on Ignition Control
Ign Ctrl Fault 5
A/D failure on Ignition Control
Ign Ctrl Fault 6
Flame sense circuit failure on Ignition Control
Ign Ctrl Fault 7
Out of sequence execution detected on Ignition Control
Hi Water Temp
Water temperature exceeded 108F
Remote Error
Both Spa and Pool inputs are energized
Hi Limit 1 Fault
High Limit 1 is open
Hi Limit 2 Fault
High Limit 2 is open
Blocked Vent
Vent/Field switch #1 is open
Vent Temp Limit
Vent Temp Limit switch is open
Clock/Fireman Sw
Clock/Fireman switch is open (Not stored in EEPROM)
Air Flow Sw Open
Air Pressure Switch open with inducer on
Air Flow Sw Closed
Air Pressure Switch closed with inducer off
5 Min Ind Off
Inducer off for 5 minutes because the inducer’s interlock didn't close
Fan Lockout
3 fan switch faults within same heat demand cycle
Ignition Failure
No flame detected within 4 seconds (Natural gas only, not stored in EEPROM)
Ign 60 min Delay
Ignition trial failed 3 times in single call for heat (Natural Gas only, not stored in EEPROM)
Ignition Lockout
Ignition trial failed on Propane
MV Output Fault
Ignition control has detected problem with gas valve output
Flame w/o CFH
Ignition Control is sensing flame present with gas valve closed
Low Temp Lockout
Ignition Control has shut down heat because water temp < 36F
EEPROM Fault
Corrupted data found on the Companion board
Ign EEPROM Fault
Corrupted data found on the Ignition Control
Low Voltage
Displayed when supply voltage < 20, no operational changes
Flue Over Temp
Heater shut off because flue temperature is too high
Flue Sense Fail
Flue Monitor is enabled and Flue temperature sensor is open or shorted
Blocked Drain
Condensate drain switch is closed
Fan RPM Fault
FAN RPM more than 500 RPM different than target
Table 11: Error Condition Messages
Содержание X94
Страница 24: ...24 Fig 10 Outdoor Venting Fig 11 3 in 1 Multi Vent Adapter ...
Страница 32: ...32 WIRING DIAGRAM Fig 26 Wiring Diagram ...
Страница 33: ...33 SECTION 4 SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS Fig 27 Location of Controls ...
Страница 46: ...46 SECTION 6 REPLACEMENT PARTS ...
Страница 47: ...47 ...
Страница 52: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ...