14
INDOOR HEATER INSTALLATION
The heater must always be vented to the outside.
See the Venting section (beginning on page 17) for details.
Minimum allowable space is shown on the nameplate.
Notes:
1. The model number prefix indicates: (S=Stainless Steel Heat Exchanger), (R=Raypak) Model number suf-
fix indicates: pilot type (E = Digital) and fuel type (P = Propane, N = Natural Gas). Example: Model number
SR-410-EN indicates a unit with digital (IID) ignition using natural gas with a stainless steel heat exchang-
er.
2. Heaters are rated for natural gas and propane up to 4,500 feet (1,371.6 m). For elevations over 4,500’
(1,371.6 m), consult the factory.
3. Flue gases must be properly vented with CAT III for horizontal and CAT IV for vertical venting. Inlet air can
be ducted with 4” (101.6 mm) metal or PVC pipe. See the venting section of this manual for complete vent-
ing details.
SPECIFICATIONS AND DIMENSIONS
Heater
Model
MBTU
Input
Dimensions
Shipping
Weight
Flue
Diameter
(B)
Air Inlet
(C)
Minimum
Flow
Maximum
Flow
SR-410
399.0
4”
4”
40 GPM
(151 LPM)
125 GPM
(473 LPM)
300 (136 kg)
Fig. 4: Specifications and Dimensions
Table 1: Specifications and Dimensions
*Dimensions are in inches and [millimeters]
Electrical Requirements:
120V/1ph/60Hz 5A
Содержание X94
Страница 24: ...24 Fig 10 Outdoor Venting Fig 11 3 in 1 Multi Vent Adapter ...
Страница 32: ...32 WIRING DIAGRAM Fig 26 Wiring Diagram ...
Страница 33: ...33 SECTION 4 SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS Fig 27 Location of Controls ...
Страница 46: ...46 SECTION 6 REPLACEMENT PARTS ...
Страница 47: ...47 ...
Страница 52: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ...