OUTDOOR HEATER INSTALLATION
X94 Professional heaters are design-certified for outdoor installation, when equipped with the approved vent ter-
minals designated for outdoor use. The heaters are designed for outdoor operation in non-freezing conditions
only. Freezing conditions may cause condensate to freeze in the condensate drain line and trap causing the unit
to shut down from a blocked condensate drain. Additionally, components of the condensate management sys-
tem may be damaged by the ice formation. Units installed in freezing climates for seasonal use must be winter-
ized to avoid freeze damage to the heater. See Winterizing Instructions on page 8.
WARNING:
The heater shall not be located in an area where water sprinklers, or other devices, may cause
water to spray through the cabinet louvers and into the heater. This could cause internal rusting or damage
electrical components, and void the warranty.
WARNING:
Do not install within 3’ (0.91 m) of a heat pump or an outdoor condensing unit. Strong air intake
from this type of equipment can disturb the combustion process and cause damage or personal injury.
CLEARANCES
ALL HEATERS
For clearances from combustible surfaces, see the
chart below.
CLEARANCE FROM
COMBUSTIBLE CONSTRUCTION
INDOOR INSTALLATIONS:
Top - 24” (609.6 mm) Back - 1” (25.4 mm)
Front - Alcove (Open) Right Side - 1” (25.4 mm)
Vent - 1” (25.4 mm)
Left Side - 1” (25.4 mm)
Floor* - 0” (0 mm)
OUTDOOR INSTALLATION
Top - Unobstructed
(Outdoor Stack)
Floor - 0” (0 mm)
Right Side - 1” (25.4 mm)
Back - 12” (304.8 mm) Left Side - 1” (25.4 mm)
*Do not install on carpeting.
When installed according to the listed minimum clear-
ances from combustible construction, the pool heater
can still be serviced without removing permanent
construction around the heater.
However,
for ease of servicing, Raypak recom-
mends a clearance of at least 24” (609.6 mm) in the
front and back.
This will enable the heater to be serv-
iced in its installed location, without movement or
removal of the heater.
FLOORING:
This heater can be installed on com-
bustible flooring.
NOTE:
The heater must be installed in a manner
that will enable the heater to be serviced without
removing any structure around the heater.
Содержание X94
Страница 24: ...24 Fig 10 Outdoor Venting Fig 11 3 in 1 Multi Vent Adapter ...
Страница 32: ...32 WIRING DIAGRAM Fig 26 Wiring Diagram ...
Страница 33: ...33 SECTION 4 SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS Fig 27 Location of Controls ...
Страница 46: ...46 SECTION 6 REPLACEMENT PARTS ...
Страница 47: ...47 ...
Страница 52: ...www raypak com Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ...