22
9. TECHNICAL PARAMETERS
Inverter Models Only
Parameter
Crosswind Inverter Models
30-I
40-I
50-I
65-I
Max intended pool volume gallons (liters)
2113
(8000)
2906
(11000)
3698
(14000)
4755
(18000)
Operating air temperature
32~109°F (0~43°C)
Performance Condition: Air 80°F (27°C), Water 80°F (27°C), Humidity 80%
Heating capacity (BTUH)
30,000
40,000
50,000
65,000
Heating capacity (BTUH) in silent mode
24,000
32,000
40,000
52,000
COP
10.0~5.8
10.3~6.0
10.6~5.98
11.2~5.61
Performance Condition: Air 80°F (27°C), Water 80°F (27°C), Humidity 63%
Heating capacity (BTUH)
28,500
38,255
47,500
56,000
Heating capacity (BTUH) in silent mode
22,800
31,000
37,200
44,800
COP
9.0~5.4
9.1~5.86
9.7~5.5
9.9~5.35
Performance Condition: Air 50°F (10°C), Water 80°F (27°C), Humidity 63%
Heating capacity (BTUH)
18,300
24,500
28,900
37,000
Heating capacity (BTUH) in silent mode
14,600
15,000
20,295
26,970
COP
4.4~4.0
4.5~4.0
5.1~4.15
5.2~4.3
Rated input power (kW)
0.2~1.5
0.23~1.95
0.28~2.45
0.34~3.4
Rated input current (A)
0.86~6.52
1~8.48
1.22~10.65
1.48~14.78
Power supply
208-230VAC/ 1 Ph/60Hz
Refrigerant (R410A) in oz.
28.2
31.7
38.8
45.9
Advised water flux GPM (L/min)
13.2~17.7
(50~67)
17.7~26.4
(67~100)
21.9~30.6
(83~116)
28.5~37.5
(108~142)
Sound pressure 39" (3 m) dBA
33.4~45.2
33.6~45.5
34.9~45.0
38.2~49.3
Heat exchanger
Titanium in PVC
Casing
ABS casing
Air discharge
Horizontal
Water pipe in-out Spec inches
1-1/2
Net Dimension LxWxH inches (mm)
34x14.1x25.5
(864x359x648)
37.8x13.7x25.9
(961x348x648)
37.8x13.7x25.9
(961x348x658)
37.8x15.4x25.9
(961x390x658)
Net Weight lbs (kg)
222.7
(101)
277.8
(126)
330.7
(150)
379.2
(172)
* The values indicated are valid under ideal conditions: Pool is well covered, filtration system running at least 15 hours a day.
* The final specs will be in accordance with the specs of the product
Table J. Technical Parameters - Inverter Models Only
6100.64_Crosswind.indd 22