background image

• Use special (supplementary) cellular services which may be avail-

able in your cellular service area (see Special Cellular Services on
page 20).

How to Use the Hookflash Function

Depending upon your phone, there are two ways to initiate the Hookflash
function:

• Press the dedicated “HOOKFLASH” or “FLASH” key on your

telephone.

• Press the hang-up or switch-hook mechanism on your phone once

quickly (approximately 1/2-second).

Important Tones and Alerts

No-Service Tone –

When cellular service is not available, the receiver emits a

No-Service (fast-beeping) tone instead of the normal (steady) dial tone.

ROH (Receiver Off-Hook) Tone –

If the telephone equipment remains off-

hook (off its cradle) with no dialing activity for 45 seconds, the receiver emits
an ROH tone for 60 seconds.

Incoming Call Alert –

If you’re dialing a number and an incoming call occurs,

the receiver will emit an audible ring. To answer the incoming call:

• Press the “HOOKFLASH” button once. This will connect the incoming call.
• OR hang-up immediately. This will cause the phone to start ringing.

How to Adjust the Volume Level

If the volume level on your phone is too high or too low, you can adjust the
levels using the keypad on your telephone.

Note: your telephone must be

in Tone-Dial 

(DTMF)

mode to adjust the levels.

To Increase Audio Level -

Increase the audio level in steps by pressing:

#  *  8  

(also known as  

#  *  Up

)

Continue to press  #  *  8  until the desired level is reached.

To Decrease Audio Level -

Decrease the audio level in steps by pressing:

#  *  3   

(also known as  #  *  

Down

)

Continue to press  #  *  3  until the desired level is reached.

NOTE: The default setting lets you adjust the audio up to three (3)
steps in either direction (Up or Down).

RAYCOM C

ELLULAR

(AMPS)

18

RAYCOM OPERATION

Содержание RAYCOM Cellular

Страница 1: ...Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine The names Raytheon and RTN are owned by the Raytheon Company...

Страница 2: ...RAYCOM CELLULAR AMPS FIXED WIRELESS TERMINAL USER MANUAL Bringing Voice FAX and Data onto your boat Manual Part No G713102 5...

Страница 3: ...nd properly How to contact Raytheon Technical Support 800 539 5539 ext 2444 or 603 881 5200 ext 2444 You may reach our Technical Support Department Monday to Friday 8 30 a m to 5 00 p m Eastern Standa...

Страница 4: ...However if you are in need of an item not available through your retailer feel free to contact our Customer Service department Monday to Friday 8 30 a m to 5 00 p m Eastern Standard Time Product Repa...

Страница 5: ...el 18 Fax Data Transmission 19 Variable Dial Time Auto SEND Delay Option 19 Special Cellular Services 20 Data After SEND In Call DTMF Signaling Option 21 Zero Dial Delay for Frequently Called Numbers...

Страница 6: ...dence of shipping damage Pre Installation Check List Before attempting RAYCOM Cellular installation make sure you have the fol lowing components tools and materials Materials Needed Qty Description Su...

Страница 7: ...lect a central location to reduce the length of the cable runs There should be adequate ventilation It should be as far apart as possible from any devices that may induce interference such as motors g...

Страница 8: ...gain antenna mounted high on a mast in rolling seas may cause the signal to fade in and out Ask your marine dealer which antenna is best suited for your application The antenna cable should not be sp...

Страница 9: ...nal of the power source and the wire connected to the NEGATIVE terminal of the power source Once connected plug the 2 5mm barrel plug into the power plug on the bottom side of the unit The LED indicto...

Страница 10: ...the programming process and answer any questions you may have Their operating hours are 6 a m to 6 p m Pacific Standard Time Monday through Friday Saturday 9 a m to 3 p m PST NOTE American Wireless p...

Страница 11: ...ng tone if correct you ll hear the programming tone again Step 4 Press 5 _ _ _ _ _ The spaces represent your 1 to 5 digit System Identifier SID which ranges from 0 to 32 767 This information identifie...

Страница 12: ...NOTE The default setting is channel 333 for A service providers To change the setting you must enter a 1 to 4 digit number in the range of 0 to 1023 For example to set up channel 565 enter 24 565 If y...

Страница 13: ...e the System Preference Press 7 _ The space represents your 1 digit system preference enter 0 for System A preferred enter 1 for System B preferred enter 2 for System A only enter 3 for System B only...

Страница 14: ...N Electronic Serial Number before you make or receive calls Once you ve entered the A Key your RAYCOM automatically verifies the code with the cel lular provider before every call There s no need to r...

Страница 15: ...d POTS telephone and listen for a dial tone If these conditions are met your antenna installation and connec tions were done correctly If any of these conditions were not met refer to the Troubleshoot...

Страница 16: ...e screws This will insure your RAYCOM stays securely in place Slide the unit off of the wall mount screws 9 Reconnect the power and phone connections Insure they are routed through either the channel...

Страница 17: ...omplete Apply power to your RAYCOM and insure you have a green LED indicator and that you have dial tone at your POTS tele phone Four rubber feet are included with your RAYCOM in the event a desk top...

Страница 18: ...produced Hang up the phone and try again 3 Dial the phone number How to Receive a Call When your telephone rings pick up the handset and begin talking How to End a Call Hang up the phone place the han...

Страница 19: ...60 seconds Incoming Call Alert If you re dialing a number and an incoming call occurs the receiver will emit an audible ring To answer the incoming call Press the HOOKFLASH button once This will conn...

Страница 20: ...nstruct the modem to wait 1 second for each comma before dialing the PIN number A Fax modem works in a similar fashion except the pause key is used in place of commas You may have to experiment with t...

Страница 21: ...e services may be available on a subscription basis However certain dialing sequences must be entered which vary among service providers Please consult your service provider for the dialing instructio...

Страница 22: ...features such in entry as call waiting three way conference calls voice mail etc Please consult your service provider for the required Data After Send In Call DTMF Signaling configuration The Data Af...

Страница 23: ...ze your fre quently called phone numbers and send them immediately without the 3 second Auto SEND Delay The RAYCOM stores a list of up to 50 numbers in its memory This list contains any number that yo...

Страница 24: ...If the LED indicator flashes red call our Product Support Department Unable to Receive Incoming Calls If more than one telephone or telephone device is connected to your RAYCOM make sure that all devi...

Страница 25: ...ilable body of research more than 120 scientists engineers and physicians from universities government health agencies and industry developed this updated Standard In March 1993 the U S Federal Commun...

Страница 26: ...rsonal medical devices such as pacemak ers hearing aids etc to determine if they are adequately shielded from exter nal RF energy Potentially Explosive Atmospheres Turn your RAYCOM Cellular OFF when i...

Страница 27: ...he user is encouraged to try to correct the interference by one or more of the follow ing measures Reorient or relocate the antenna Increase the separation between the equipment and the terminal Conne...

Страница 28: ...Enter the Technician Programming Mode Use the following access code to enter the Programming mode Press 0 1 2 3 4 4 3 2 1 The access code is 8 digits If the access code is not 8 digits or does not ma...

Страница 29: ...ll not update or store this value the existing stored parameter will remain The factory default setting is 1 How to Set the Roam Option Use the following key sequence to set the Roam option Press 6 Ro...

Страница 30: ...represent the 1 digit Pulse Dial option enter 0 to disable pulse dialing capability enter 1 to enable pulse dialing capability You must enter either 0 or 1 otherwise the FWT will not update or store t...

Страница 31: ...lay option enter 1 to enable Zero Dial Delay option You must enter either 0 or 1 otherwise the FWT will not update or store this value the existing stored parameter will remain The factory default set...

Отзывы: