background image

ICNIRP Guidelines

When properly installed and operated, the use of
this Radar conforms to: ICNIRP Guidelines 1998 -
International Commission on Non-Ionising Radiation
Protection: Guidelines for limiting exposure to
time-varying electric, magnetic and electro-magnetic
fields (up to 300GHz) 1998.

Water ingress

Water ingress disclaimer

Although the waterproof rating capacity of this
product meets the stated IPX standard (refer to the
product’s

Technical Specification

), water intrusion

and subsequent equipment failure may occur if the
product is subjected to commercial high-pressure
washing. Raymarine will not warrant products
subjected to high-pressure washing.

Disclaimer

Raymarine does not warrant that this product is
error-free or that it is compatible with products
manufactured by any person or entity other than
Raymarine.

Raymarine is not responsible for damages or injuries
caused by your use or inability to use the product,
by the interaction of the product with products
manufactured by others, or by errors in information
utilized by the product supplied by third parties.

EMC installation guidelines

Raymarine equipment and accessories conform to
the appropriate Electromagnetic Compatibility (EMC)
regulations, to minimize electromagnetic interference
between equipment and minimize the effect such
interference could have on the performance of your
system

Correct installation is required to ensure that EMC
performance is not compromised.

Note:

In areas of extreme EMC interference,

some slight interference may be noticed on the
product.Where this occurs the product and the
source of the interference should be separated by
a greater distance.

For

optimum

EMC performance we recommend

that wherever possible:

• Raymarine equipment and cables connected to

it are:

– At least 1m (3ft) from any equipment transmitting

or cables carrying radio signals e.g. VHF radios,
cables and antennas. In the case of SSB radios,
the distance should be increased to 7 ft (2 m).

– More than 2m (7ft) from the path of a radar

beam. A radar beam can normally be assumed
to spread 20 degrees above and below the
radiating element.

• The product is supplied from a separate battery

from that used for engine start. This is important to
prevent erratic behavior and data loss which can
occur if the engine start does not have a separate
battery.

• Raymarine specified cables are used.

• Cables are not cut or extended, unless doing so is

detailed in the installation manual.

Note: Where constraints on the installation
prevent any of the above recommendations

,

always ensure the maximum possible separation
between different items of electrical equipment, to
provide the best conditions for EMC performance
throughout the installation

Compass safe distance

To prevent potential interference with the vessel's
magnetic compasses, ensure an adequate distance
is maintained from the product.

When choosing a suitable location for the product
you should aim to maintain the maximum possible
distance from any compasses. Typically this distance
should be at least 1 m (3 ft) in all directions. However
for some smaller vessels it may not be possible to
locate the product this far away from a compass. In
this situation, when choosing the installation location
for your product, ensure that the compass is not
affected by the product when it is in a powered state.

Declaration of conformity

Raymarine UK Ltd. declares that this product is
compliant with the essential requirements of R&TTE
directive 1999/5/EC.

Connections to other equipment

Requirement for ferrites on non-Raymarine cables

If your Raymarine equipment is to be connected
to other equipment using a cable not supplied by
Raymarine, a suppression ferrite MUST always be
attached to the cable near the Raymarine unit.

Product disposal

Dispose of this product in accordance with the
WEEE Directive.

The Waste Electrical and Electronic Equipment

(WEEE) Directive requires the recycling of waste
electrical and electronic equipment.

8

Содержание Quantum Radome

Страница 1: ...INSTALLATION INSTRUCTIONS Quantum Radar...

Страница 2: ...imed trademarks of FLIR Systems Inc All other trademarks trade names or company names referenced herein are used for identification only and are the property of their respective owners This product is...

Страница 3: ...passcode 16 3 3 Multifunction display compatibility 17 Compatible multifunction displays 17 Incompatible multifunction displays 17 3 4 Multifunction display software requirements 17 Software updates 1...

Страница 4: ...adar scanner over RayNet 44 Powering on a Quantum Radar 44 Pairing with a Quantum Radar using Wi Fi 44 MFD access point connection when connected to Quantum Wi Fi 45 Standby and sleep modes for Wi Fi...

Страница 5: ...nstall this product Do NOT connect or disconnect equipment with the power switched on unless instructed in this document Caution Power supply protection When installing this product ensure the power s...

Страница 6: ...les and antennas In the case of SSB radios the distance should be increased to 7 ft 2 m More than 2m 7ft from the path of a radar beam A radar beam can normally be assumed to spread 20 degrees above a...

Страница 7: ...Raymarine Incorporated could violate compliance with FCC rules and void the operator s authority to operate the equipment Technical accuracy To the best of our knowledge the information in this docume...

Страница 8: ...ter 2 Document and product information Chapter contents 2 1 Document information on page 12 2 2 Parts supplied on page 13 2 3 Quantum Radome product overview on page 13 Document and product informatio...

Страница 9: ...umentation for your product please Refer to the product s core model number which can be found listed on the label on the rear or underside of your product or accessed from any Raymarine multifunction...

Страница 10: ...rovides a map like representation of the area around your vessel enabling you to identify other vessels buoys and land features such as coastlines and hills The Quantum Radome has the following featur...

Страница 11: ...16 3 3 Multifunction display compatibility on page 17 3 4 Multifunction display software requirements on page 17 3 5 Tools required on page 18 3 6 Typical systems on page 18 3 7 Product dimensions on...

Страница 12: ...electronics and requires the following additional components for full operation Compatible Raymarine multifunction display Refer to Compatible multifunction displays for a list of compatible multifun...

Страница 13: ...400 3 4 Multifunction display software requirements The operation of this product requires that your Raymarine LightHouseTM powered MFD is running LightHouseTM software version 17 or later Caution Ins...

Страница 14: ...from your planned installation For information on how to connect the products refer to the relevant Cables and connections section for your Quantum variant For information on available cables and acce...

Страница 15: ...searchlights horns masts etc see Shadow areas and false echoes for additional information Clear of heat and fumes At least 1m 3ft from a magnetic compass or other scanners Shadow areas and false echoe...

Страница 16: ...beamwidths of the 2 scanners In all cases you should aim to achieve as much physical separation as possible to minimize any potential interference 3 9 Quantum Wi Fi only installation requirements Whi...

Страница 17: ...ing a location for your Quantum Radar that will be connected using a Wi Fi connection it is important to consider the effects your surroundings can have on the Wi Fi signal The Wi Fi signal will refle...

Страница 18: ...mescreen Set up Wireless connection Wi Fi Wi Fi Sharing Wi Fi Name 4 Go to the location you have chosen for your Radar 5 Open the Wi Fi Analyzer app on your smart device and scan available networks 6...

Страница 19: ...r is determined independently by each device manufacturer However in general the performance will be similar 1 4 Unable to maintain a connection usually accompanied by very poor connection speed Light...

Страница 20: ...et Chapter contents 4 1 Wi Fi only Quantum variants on page 26 4 2 General cabling guidance on page 26 4 3 Connections overview on page 27 4 4 Power connection on page 30 4 5 Network connection on pag...

Страница 21: ...damage and exposure to heat Use trunking or conduit where possible Do NOT run cables through bilges or doorways or close to moving or hot objects Secure cables in place using tie wraps or lacing twin...

Страница 22: ...the extra weight of the cable 4 3 Connections overview Use the following information to help you identify the connections on your product Connector Connects to Suitable cables RayNet network or devic...

Страница 23: ...plied with a RayNet cable Refer to the Chapter 2 Document and product information section for more information Refer to the 11 4 RayNet to RayNet cables and connectors section for information on suita...

Страница 24: ...d with a combined power data Digital Radar cable you can use a Y adapter part number A80308 to connect the existing cable end to the scanner s connectors 1 Ensure that the vessel s power supply is swi...

Страница 25: ...roducts in your system such as sonar modules can create voltage peaks at certain times which may impact the voltage available to other products during the peaks Power distribution Recommendations and...

Страница 26: ...f equipment shares a breaker use individual in line fuses for each power circuit to provide the necessary protection In all cases observe the recommended breaker fuse ratings provided in the product s...

Страница 27: ...e multifunction display with Wi Fi capability 2 Quantum Radome 3 Wi Fi datalink Refer to the Chapter 7 System checks and troubleshooting section and to your MFD documentation for further information a...

Страница 28: ...Quantum variant with Wi Fi only Chapter contents 5 1 General cabling guidance on page 34 5 2 Power cable routing Wi Fi variant only on page 35 5 3 Power connection on page 35 Cables and connections Qu...

Страница 29: ...ill not pull out under extreme sea conditions Circuit isolation Appropriate circuit isolation is required for installations using both AC and DC current Always use isolating transformers or a separate...

Страница 30: ...nnection to 12V 24V power supply Power supply 4 Black cable negative Power supply s negative terminal In line fuse and thermal breaker ratings The following in line fuse and thermal breaker ratings ap...

Страница 31: ...res need to be connected If the supplied power cable is NOT fitted with an inline fuse you MUST fit a suitably rated fuse or breaker between the red wire and the battery s positive terminal Refer to t...

Страница 32: ...tailed in the following standards BMEA Code of Practice for Electrical and Electronic Installations in Boats NMEA 0400 Installation Standard ABYC E 11 AC DC Electrical Systems on Boats ABYC A 31 Batte...

Страница 33: ...Chapter 6 Mounting Chapter contents 6 1 Mounting pre requisite breather holes on page 40 6 2 Mounting the scanner on page 40 6 3 Radar scanner protection sailing vessels on page 42 Mounting 39...

Страница 34: ...e to the mounting platform ensuring that the arrow on the template is pointed towards the front of the vessel 2 Drill 3mm pilot holes in the four positions shown on the template 3 Drill out the pilot...

Страница 35: ...tum Radar scanners Only 1 one Quantum Radar scanner can be used at any one time per networked system If you have more than one Quantum Radar scanner installed on your vessel and want to use them at th...

Страница 36: ...unit or the bracket Raymarine strongly recommends that you check the condition and security of the bracket mounting feet the security lanyard s the Radar scanner guard and the Radar scanner unit itsel...

Страница 37: ...Chapter 7 System checks and troubleshooting Chapter contents 7 1 Post installation procedures on page 44 7 2 Troubleshooting on page 46 System checks and troubleshooting 43...

Страница 38: ...h also supports Wi Fi During pairing the Wi Fi credentials of all MFDs with Wi Fi switched on are sent to the Quantum Radar At subsequent power cycles the Quantum Radar will automatically connect to t...

Страница 39: ...it s important to understand how these modes can potentially impact the pairing process Sleep mode If the connection to the MFD is lost while the scanner is in Standby mode the scanner will switch to...

Страница 40: ...prior to packing and shipping subjected to comprehensive test and quality assurance programs However if you experience problems with the operation of your product this section will help you to diagnos...

Страница 41: ...procedure described in the MFD Operations manual Multiple Quantum Radars more information Only 1 one Quantum Radar scanner can be powered at any one time per networked system It is possible to have 1...

Страница 42: ...t to Possible cause Possible solutions Incorrect network credentials Ensure you are using the correct passphrase the Wi Fi network s passphrase can be found in the Wi Fi settings on the broadcasting d...

Страница 43: ...Wi Fi traffic Network connection established but no data Possible cause Possible solutions Connected to the wrong network Ensure that your devices is connected to the correct network Device software i...

Страница 44: ...Chapter 8 Maintenance Chapter contents 8 1 Maintenance on page 52 8 2 Unit cleaning instructions on page 52 Maintenance 51...

Страница 45: ...ther maintenance tasks with the Radar powered off Ensure the antenna is firmly attached to the mounting surface Check that any connected cables are in good condition and securely attached Examine all...

Страница 46: ...hapter 9 Technical support Chapter contents 9 1 Raymarine product support and servicing on page 54 9 2 Operation instructions on page 55 9 3 Viewing product information on page 55 Technical support 53...

Страница 47: ...mpatible multifunction display This option displays information such as product serial number and software version With the Homescreen displayed 1 Select Set up 2 Select Maintenance 3 Select Diagnosti...

Страница 48: ...Chapter 10 Technical specification Chapter contents 10 1 Technical specification on page 58 Technical specification 57...

Страница 49: ...e Storage temperature range Additional storage conditions Humidity Maximum wind speed IPX6 10 C to 55 C 25 C to 70 C Store upright do not block vents on underside Up to 95 at 35 C 100kts Range scales...

Страница 50: ...s 11 1 Quantum Radar accessories on page 60 11 2 Network hardware on page 60 11 3 Network cable connector types on page 61 11 4 RayNet to RayNet cables and connectors on page 62 11 5 RayNet to RJ45 ad...

Страница 51: ...itable adapter cables RJ45 SeaTalkhs network switch E55058 8 port switch for network connection of multiple SeaTalkhs devices featuring RJ45 connectors RJ45 SeaTalkhs crossover coupler E55060 Enables...

Страница 52: ...11 3 Network cable connector types There are 2 types of network cable connector RayNet and RJ45 SeaTalkhs RJ45 SeaTalkhs connector RayNet connector Spares and accessories 61...

Страница 53: ...abling you to pull the cables through conduits and other obstacles 5 3 RayNet to RayNet right angle coupler adapter Suitable for connecting RayNet cables at 90 right angle to devices for installations...

Страница 54: ...ouse MFD 1 3 Adapter cable with a RayNet male plug on one end and an RJ45 SeaTalkhs waterproof male plug on the other end Connect a legacy G Series GPM 400 C Series Widescreen or E Series Widescreen M...

Отзывы: