background image

Radar scanner mounting angle

Ensure the Radar scanner rotates parallel to the
water line.

The Radar beam from the Radar scanner is
approximately 20° wide in the vertical direction, to
give good target detection even when your vessel
pitches and rolls.

Planing hull vessels, and some displacement hull
vessels, adopt a higher bow angle when the vessel is
at cruising speed. This may raise the Radar’s main
radiation angle, and can cause poor detection of
nearby targets. It may be necessary to compensate
for the bow rise to ensure optimum target detection.
This can be achieved by fitting a wedge or washers
between the mounting platform and the base of the
Radar scanner, so that the Radar beam remains
parallel to the water line when the vessel's bow rises
at cruising speed.

Item

Description

1

Wedge or washers

Multiple Radar scanners — location
requirements

Important location considerations when installing
multiple radar scanners on the same vessel.

• Scanners should be mounted above each other,

vertically separated by at least 0.5m (1.6ft). This
applies to all installation locations on the vessel.

• Multiple scanners should be mounted in a way

that minimizes interference between the vertical
beamwidths of the 2 scanners.

• In all cases, you should aim to achieve as much

physical separation as possible, to minimize any
potential interference.

3.9 Quantum Wi-Fi only
installation requirements

Whilst the Wi-Fi performance has been tested and
proven in many different installation scenarios, the
requirements below must be taken into consideration
before choosing a location for the Quantum

Radar.

In systems with multiple MFDs, the Radar should
be connected to the MFDs that are located closest
to it, or to the MFDs with the clearest line of sight to
the Radar.

The maximum distance between MFD and Radar
will vary depending on the installation environment
(i.e. obstructions and interference).

Example 1 — Open air, line of sight in optimum
conditions

In optimum open air, clear line-of-sight conditions a
reliable connection is possible at distances up to 100
m (328 feet). However, there are many factors that
can influence this so a pre-installation site survey
should always be performed. For reliable Wi-Fi
performance the signal strength should be better
than –75dBm. The closer the signal is to zero the
better the Wi-Fi performance will be (e.g. –40dBm is
better than –75dBm). You can assess the potential
signal strength at the desired location during the
Pre-installation Site Survey using a Wi-Fi Analyzer
app on your smart device.

Example 2 — Signal passing through Fiberglass
coach roof

20

Содержание Quantum Radome

Страница 1: ...INSTALLATION INSTRUCTIONS Quantum Radar...

Страница 2: ...imed trademarks of FLIR Systems Inc All other trademarks trade names or company names referenced herein are used for identification only and are the property of their respective owners This product is...

Страница 3: ...passcode 16 3 3 Multifunction display compatibility 17 Compatible multifunction displays 17 Incompatible multifunction displays 17 3 4 Multifunction display software requirements 17 Software updates 1...

Страница 4: ...adar scanner over RayNet 44 Powering on a Quantum Radar 44 Pairing with a Quantum Radar using Wi Fi 44 MFD access point connection when connected to Quantum Wi Fi 45 Standby and sleep modes for Wi Fi...

Страница 5: ...nstall this product Do NOT connect or disconnect equipment with the power switched on unless instructed in this document Caution Power supply protection When installing this product ensure the power s...

Страница 6: ...les and antennas In the case of SSB radios the distance should be increased to 7 ft 2 m More than 2m 7ft from the path of a radar beam A radar beam can normally be assumed to spread 20 degrees above a...

Страница 7: ...Raymarine Incorporated could violate compliance with FCC rules and void the operator s authority to operate the equipment Technical accuracy To the best of our knowledge the information in this docume...

Страница 8: ...ter 2 Document and product information Chapter contents 2 1 Document information on page 12 2 2 Parts supplied on page 13 2 3 Quantum Radome product overview on page 13 Document and product informatio...

Страница 9: ...umentation for your product please Refer to the product s core model number which can be found listed on the label on the rear or underside of your product or accessed from any Raymarine multifunction...

Страница 10: ...rovides a map like representation of the area around your vessel enabling you to identify other vessels buoys and land features such as coastlines and hills The Quantum Radome has the following featur...

Страница 11: ...16 3 3 Multifunction display compatibility on page 17 3 4 Multifunction display software requirements on page 17 3 5 Tools required on page 18 3 6 Typical systems on page 18 3 7 Product dimensions on...

Страница 12: ...electronics and requires the following additional components for full operation Compatible Raymarine multifunction display Refer to Compatible multifunction displays for a list of compatible multifun...

Страница 13: ...400 3 4 Multifunction display software requirements The operation of this product requires that your Raymarine LightHouseTM powered MFD is running LightHouseTM software version 17 or later Caution Ins...

Страница 14: ...from your planned installation For information on how to connect the products refer to the relevant Cables and connections section for your Quantum variant For information on available cables and acce...

Страница 15: ...searchlights horns masts etc see Shadow areas and false echoes for additional information Clear of heat and fumes At least 1m 3ft from a magnetic compass or other scanners Shadow areas and false echoe...

Страница 16: ...beamwidths of the 2 scanners In all cases you should aim to achieve as much physical separation as possible to minimize any potential interference 3 9 Quantum Wi Fi only installation requirements Whi...

Страница 17: ...ing a location for your Quantum Radar that will be connected using a Wi Fi connection it is important to consider the effects your surroundings can have on the Wi Fi signal The Wi Fi signal will refle...

Страница 18: ...mescreen Set up Wireless connection Wi Fi Wi Fi Sharing Wi Fi Name 4 Go to the location you have chosen for your Radar 5 Open the Wi Fi Analyzer app on your smart device and scan available networks 6...

Страница 19: ...r is determined independently by each device manufacturer However in general the performance will be similar 1 4 Unable to maintain a connection usually accompanied by very poor connection speed Light...

Страница 20: ...et Chapter contents 4 1 Wi Fi only Quantum variants on page 26 4 2 General cabling guidance on page 26 4 3 Connections overview on page 27 4 4 Power connection on page 30 4 5 Network connection on pag...

Страница 21: ...damage and exposure to heat Use trunking or conduit where possible Do NOT run cables through bilges or doorways or close to moving or hot objects Secure cables in place using tie wraps or lacing twin...

Страница 22: ...the extra weight of the cable 4 3 Connections overview Use the following information to help you identify the connections on your product Connector Connects to Suitable cables RayNet network or devic...

Страница 23: ...plied with a RayNet cable Refer to the Chapter 2 Document and product information section for more information Refer to the 11 4 RayNet to RayNet cables and connectors section for information on suita...

Страница 24: ...d with a combined power data Digital Radar cable you can use a Y adapter part number A80308 to connect the existing cable end to the scanner s connectors 1 Ensure that the vessel s power supply is swi...

Страница 25: ...roducts in your system such as sonar modules can create voltage peaks at certain times which may impact the voltage available to other products during the peaks Power distribution Recommendations and...

Страница 26: ...f equipment shares a breaker use individual in line fuses for each power circuit to provide the necessary protection In all cases observe the recommended breaker fuse ratings provided in the product s...

Страница 27: ...e multifunction display with Wi Fi capability 2 Quantum Radome 3 Wi Fi datalink Refer to the Chapter 7 System checks and troubleshooting section and to your MFD documentation for further information a...

Страница 28: ...Quantum variant with Wi Fi only Chapter contents 5 1 General cabling guidance on page 34 5 2 Power cable routing Wi Fi variant only on page 35 5 3 Power connection on page 35 Cables and connections Qu...

Страница 29: ...ill not pull out under extreme sea conditions Circuit isolation Appropriate circuit isolation is required for installations using both AC and DC current Always use isolating transformers or a separate...

Страница 30: ...nnection to 12V 24V power supply Power supply 4 Black cable negative Power supply s negative terminal In line fuse and thermal breaker ratings The following in line fuse and thermal breaker ratings ap...

Страница 31: ...res need to be connected If the supplied power cable is NOT fitted with an inline fuse you MUST fit a suitably rated fuse or breaker between the red wire and the battery s positive terminal Refer to t...

Страница 32: ...tailed in the following standards BMEA Code of Practice for Electrical and Electronic Installations in Boats NMEA 0400 Installation Standard ABYC E 11 AC DC Electrical Systems on Boats ABYC A 31 Batte...

Страница 33: ...Chapter 6 Mounting Chapter contents 6 1 Mounting pre requisite breather holes on page 40 6 2 Mounting the scanner on page 40 6 3 Radar scanner protection sailing vessels on page 42 Mounting 39...

Страница 34: ...e to the mounting platform ensuring that the arrow on the template is pointed towards the front of the vessel 2 Drill 3mm pilot holes in the four positions shown on the template 3 Drill out the pilot...

Страница 35: ...tum Radar scanners Only 1 one Quantum Radar scanner can be used at any one time per networked system If you have more than one Quantum Radar scanner installed on your vessel and want to use them at th...

Страница 36: ...unit or the bracket Raymarine strongly recommends that you check the condition and security of the bracket mounting feet the security lanyard s the Radar scanner guard and the Radar scanner unit itsel...

Страница 37: ...Chapter 7 System checks and troubleshooting Chapter contents 7 1 Post installation procedures on page 44 7 2 Troubleshooting on page 46 System checks and troubleshooting 43...

Страница 38: ...h also supports Wi Fi During pairing the Wi Fi credentials of all MFDs with Wi Fi switched on are sent to the Quantum Radar At subsequent power cycles the Quantum Radar will automatically connect to t...

Страница 39: ...it s important to understand how these modes can potentially impact the pairing process Sleep mode If the connection to the MFD is lost while the scanner is in Standby mode the scanner will switch to...

Страница 40: ...prior to packing and shipping subjected to comprehensive test and quality assurance programs However if you experience problems with the operation of your product this section will help you to diagnos...

Страница 41: ...procedure described in the MFD Operations manual Multiple Quantum Radars more information Only 1 one Quantum Radar scanner can be powered at any one time per networked system It is possible to have 1...

Страница 42: ...t to Possible cause Possible solutions Incorrect network credentials Ensure you are using the correct passphrase the Wi Fi network s passphrase can be found in the Wi Fi settings on the broadcasting d...

Страница 43: ...Wi Fi traffic Network connection established but no data Possible cause Possible solutions Connected to the wrong network Ensure that your devices is connected to the correct network Device software i...

Страница 44: ...Chapter 8 Maintenance Chapter contents 8 1 Maintenance on page 52 8 2 Unit cleaning instructions on page 52 Maintenance 51...

Страница 45: ...ther maintenance tasks with the Radar powered off Ensure the antenna is firmly attached to the mounting surface Check that any connected cables are in good condition and securely attached Examine all...

Страница 46: ...hapter 9 Technical support Chapter contents 9 1 Raymarine product support and servicing on page 54 9 2 Operation instructions on page 55 9 3 Viewing product information on page 55 Technical support 53...

Страница 47: ...mpatible multifunction display This option displays information such as product serial number and software version With the Homescreen displayed 1 Select Set up 2 Select Maintenance 3 Select Diagnosti...

Страница 48: ...Chapter 10 Technical specification Chapter contents 10 1 Technical specification on page 58 Technical specification 57...

Страница 49: ...e Storage temperature range Additional storage conditions Humidity Maximum wind speed IPX6 10 C to 55 C 25 C to 70 C Store upright do not block vents on underside Up to 95 at 35 C 100kts Range scales...

Страница 50: ...s 11 1 Quantum Radar accessories on page 60 11 2 Network hardware on page 60 11 3 Network cable connector types on page 61 11 4 RayNet to RayNet cables and connectors on page 62 11 5 RayNet to RJ45 ad...

Страница 51: ...itable adapter cables RJ45 SeaTalkhs network switch E55058 8 port switch for network connection of multiple SeaTalkhs devices featuring RJ45 connectors RJ45 SeaTalkhs crossover coupler E55060 Enables...

Страница 52: ...11 3 Network cable connector types There are 2 types of network cable connector RayNet and RJ45 SeaTalkhs RJ45 SeaTalkhs connector RayNet connector Spares and accessories 61...

Страница 53: ...abling you to pull the cables through conduits and other obstacles 5 3 RayNet to RayNet right angle coupler adapter Suitable for connecting RayNet cables at 90 right angle to devices for installations...

Страница 54: ...ouse MFD 1 3 Adapter cable with a RayNet male plug on one end and an RJ45 SeaTalkhs waterproof male plug on the other end Connect a legacy G Series GPM 400 C Series Widescreen or E Series Widescreen M...

Отзывы: