6.3 Radar troubleshooting
Problems with the radar and their possible causes and solutions are described here.
Problem
Possible causes
Possible solutions
Check that the scanner power supply cable is sound and that all connections
are tight and free from corrosion.
Check relevant fuses and breakers.
Radar scanner power supply
Check power source is of the correct voltage and sufficient current (using
voltage booster if appropriate).
Check that the Scanner is correctly connected to a SeaTalk
hs
switch or
crossover coupler (as applicable).
Check the status of the SeaTalk
hs
switch.
SeaTalk
hs
network problem
Check that SeaTalk
hs
cables are free from damage.
Software mismatch between equipment
may prevent communication.
Contact Raymarine technical support.
No Data or No scanner message
Switch at scanner pedestal in OFF
position
Ensure scanner pedestal switch is in ON position.
Radar will not initialize (Voltage control
module (VCM) stuck in “sleep mode”
Intermittent or poor power connection
Check power connection at VCM. (Voltage at input = 12 / 24 V, Voltage
at output = 40 V)
The bearing of a target on the radar
screen is incorrect.
The radar bearing alignment requires
correcting.
Check and adjust radar bearing alignment.
92
e7 / e7D — Installation instructions
Содержание e7
Страница 2: ......
Страница 4: ......
Страница 12: ...12 e7 e7D Installation instructions...
Страница 64: ...64 e7 e7D Installation instructions...
Страница 74: ...74 e7 e7D Installation instructions...
Страница 88: ...88 e7 e7D Installation instructions...
Страница 108: ...108 e7 e7D Installation instructions...
Страница 109: ...Chapter 8 Technical specification Chapter contents 8 1 Technical specification on page 110 Technical specification 109...
Страница 113: ...Chapter 9 Options and accessories Chapter contents 9 1 Spares and accessories on page 114 Options and accessories 113...
Страница 122: ...122 e7 e7D Installation instructions...
Страница 123: ......
Страница 124: ...www raymarine com...