2. Ensure that the device being connected has been installed in accordance with the installation
instructions supplied with that device.
3. Ensuring correct orientation, push cable connectors fully onto the corresponding connectors.
4. Engage any locking mechanism to ensure a secure connection (e.g.: turn locking collars
clockwise until tight, or in the locked position).
5. Ensure any bare ended wire connections are suitably insulated to prevent shorting and corrosion
due to water ingress.
4.2 Power connection
The power cable must be connected to a 12 V dc power supply, this can be achieved by connecting
directly to a battery, or via the distribution panel. For 24 V vessels a suitable voltage converter is
required. The product is protected against reverse polarity.
1.
Power/NMEA 2000 cable connects to the rear of the display.
2. Ground wire connects to RF ground point, if no ground point is available connect to the battery
negative (-) terminal.
3.
Positive (Red) wire connects to battery positive (+) terminal.
4.
Waterproof fuse holder with 7 A fuse must be fitted (not supplied)
5. Negative wire connects to battery negative (-) terminal.
In-line fuse and thermal breaker ratings
The following in-line fuse and thermal breaker ratings apply to your product:
In-line fuse rating
Thermal breaker rating
7 A
7 A
Note:
• The suitable fuse rating for the thermal breaker is dependent on the number of devices you are
connecting. If in doubt consult an authorized Raymarine dealer.
• Your product’s power cable may have an in-line fuse fitted, if not then you must add an in-line
fuse / breaker to the positive wire of your product’s power connection.
Caution: Power supply protection
When installing this product ensure the power source is adequately protected by
means of a suitably-rated fuse or thermal circuit breaker.
39