Menu Path:
Setup > Enter Password (Default 00000) > SYS Setting: (CONTINUED)
Menu Path:
Setup > Enter Password (Default 00000) > BAT Setting
Menu Path:
Setup > Enter Password (Default 00000) > SYS Setting: (CONTINUED)
DOD Enable
Enable
Depth of discharge. This should always be enabled.
Disabling will result in the battery discharging to 0%
Generator
Disable
This option allows the user to install a secondary means
of generation. For example, wind generator or diesel
CT option is used for measuring the system current
Meter
Estron
Acrel
Rayleigh
Meter option is used for measuring the system current
AC Couple
Disable
Allows the user to connect an external inverter to the
system (either instead of PV, or in-addition to PC -
CT Direction
Positive
Reverses the direction of current flow measurment
ISLAND
Enable
When enabled, the inverter will continue to export
power via the BACKUP port in the event grid
SYS
Setting
CT or METER
CT
Disable
Enable
Positive
Negative
Disable
Enable
Disable
Enable
Disable
Enable
CT
BAT Type
RI-MOD 5.1
Shows the user what type of battery is connected to the
system
DISC Depth
90%
Sets the maximum depth of discharge during grid
connected state
OFFGRID
DOD
90%
Sets the maximum depth of discharge when off-grid
CHG CURR
60A
Sets the maximum battery charge current
DISC Power
80%
Sets the maximum discharge power - % of rated output
CHG Power
100%
Sets the maximum charge power - % of rated output
BAT End Volt
43.2V
Sets the voltage that is seen as 0% remaining
If enabled the battery will contantly monitor state of
charge and depth of discharge. If time option is selected,
the battery will wake up and check the state of charge
and depth of discharge at the interval set
Time
Set time
If time is selected the user will be prompted to enter a
value 0…300 minutes
Heating FLIM
Automatic
Allows the user to enable or disable the heating film
installed within the battery modules. Automatic means
the system measures the Outside temperature and turns
the film on as needed. Only applicable if heating film is
requested at time of ordering
BMS DOD
Disable
Leave disabled. The inverter will monitor depth of
discharge.
Maintain SOC
Enable
Disable: The minimum SOC will not be maintained.
Enable: The minimum SOC 2% is maintained. When
the battery SOC is less than 2%, the grid charges the
battery pack to 5% through the inverter.
Force Wake
Disable
Enabling this option means the battery will always
remain online and will not go to sleep
Enable
BAT Setting
BAT Wake-up
0…100%
0…48V
Enable
Automatic
ON
OFF
Lead Acid
RI-MOD 5.1
0…100A
0…100%
0...100%
0…100%
Disable
Enable
Disable
Enable
Disable
Enable