Step 3: Remove any debris. Secure the battery module to the wall using the supplied mounting screws and M6
washers. On the last battery module of the stack, leave the two central screws unfitted
and proceed to
the next section for
Inverter Installation
M6 Washers
Step 4: Repeat steps 1-3 for any additional batteries. Please note, for installs with more than 2 battery modules
it will be necessary to start a second battery stack to the right-hand side of the firs
t.
Inverter Installation
Step 1: Place the wall mounting bracket included with the inverter against the wall and mark the two top holes.
Using an 8mm masonry drill bit, drill 2 x holes approximately 70mm depth. Gently tap supplied nylon
wall plugs in to the holes.
Ø