e. Screw the swivel nut onto the threaded sleeve. This seals the AC connector and provides strain relief for
the AC cable. When doing so, hold the bush insert firmly by the locking cap. This ensures that the s
wivel nut
can be screwed firml
y onto the threaded sleeve.
e
f. Assembly the plug shell adapter as below picture, push the adapter and shell by hand until a “Click” is heard
or felt.
f
g. Plug the AC connector into the jack for the AC connection by hand until a “Click” is heard or felt.
2. Use tool to clamp the AC wiring terminal and wire rod; screw the nut, but do not tighten it. Make sure that
the cable is free to pass through the waterproof components. Once the terminal is connected to the right side
of the inverter, tighten the nut.
Page 24
NOTE: Maximum input power per MPPT must not exceed 2400W (3.68kW)/ 3250W (5.0kW). If a single
string is attached, a ‘Y’ Splitter must be used and the input shared across both MPPT inputs in ‘Parallel’
PV mode.