Menu Path:
Setup > Enter Password (Default 00000) > SYS Setting:
Self
Consume
Charge
from
Grid:
Enable
Disable
Enable
The energy generated by the solar panels will be used in
the following order: Feed the home loads; Charge the
battery and then, feed into the grid. When the sun is not
present, the load will be supported by the battery to
enhance self-consumption. If the power supply from the
batteries is not sufficient, the grid will support the load
demand.
Time
Setting
This mode is designed for time-use mode. The customer
can set up the desired charging/discharging time &
power via the inverter screen or APP.
Charge
Manually forces the system to charge the batteries from
the grid
DISCHG
Manually forces the system to discharge to the
connected load
Disable
The battery is only used as a backup power supply when
the grid fails. As long as the grid works, the batteries
won’t be used to power the loads. The battery is charged
with the power generated by the PV system or from the
grid.
Allows the user to set the export to grid limit
If Enable is selected, the user will be prompted to enter
the power
DRM Enable
Disable
Only applicable in Austrailia and New Zealand at this
time
EPS Enable
Disable
Enables the Backup output (the Load Switch needs to be
turned ON).
Remote CTRL
Disable
Allows control via RS485 (Scada system for example)
Start Delay
180s (when
set to UK)
This is the boot delay from when power is applied to the
inverter
CEI SPI Ctrl
Disable
This function is only applicable to use via DRM for
remote control (Australian and New zealand markets
only)
GFCICHK ENB
Enable
Ground fault monitoring on the AC grid connection
Allows the user to select the mode of discharge. Rated
power means that the applied discharge power
percentage. Load priority mean that the system supplies
the full output to drive the load
Allows the user to change the PV array configuration
(wiring changes would also apply!)
Disable
Independent
CV
Parallel
Rated power
Load priority
Disable
SYS
Setting
Zero export
Enable
DISC MODE
Rated power
Independent
Work Mode
PV input
Peak SFT
Disable
Enable
Disable
Enable
BAT Priority
Disable
Disable
Enable
Disable
Enable
Disable
Enable
20…300