70
(2) Contact customer service if error warning continues.
INV Abnormal
F18
(1) Please contact the distributor.
Communicatio
n Fault
F32
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
Grid Fault
W00
W01
W02
W03
(1) Check if the local voltage and frequency is in compliance with
the machine specification;
(2) If voltage and frequency are within the accepted range, then
wait 2 minutes for the inverter to function normally; but if no
recovery or fault repeats, please contact the local inverter
customer service;
(3) Contact the local power company if voltage and frequency are
beyond range or unstable.
Solar Loss
W04
(1) PV is not connected;
(2) Check grid connection;
(3) Check PV availability.
Bat Loss
W05
(1) Battery is not connected;
(2) Check if battery wiring port is short circuited;
(3) Contact customer service if error warning continues.
Bat Volt Low
W06
W07
(1) Check the battery availability;
(2) Contact customer service if error warning continues.
Bat Volt High
W08
(1) Check if the battery is in line with the presetting;
(2) If so, power off and restart;
(3) Contact customer service if error warning continues.
Over Load
Warning
W09
(1) Wait one minute for the inverter to restart;
(2) Check whether the load is in compliance with the specification;
GFCI Over
W10
(1) Check PV string for direct or indirect grounding phenomenon;
(2) Check peripherals of machine for current leakage;
(3) Contact the local inverter customer service if fault remains
unremoved.
LN Reverse
W11
(1) Check whether the installation follows the instructions;
(2) Contact customer service if error warning continues.
Fan Fault
W12
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
BMS Fault
W14~
W27
(1) Please contact the distributor.
CT
Reverse
W28
(1) Perform CT self-check;
(2) Contact customer service if error warning continues.
Grid Volt Lock
Fail
W29
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
PV off
W30
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
System Reset
W31
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
Содержание RI-ENERGYFLOW-3P-MODULAR...
Страница 4: ...4...
Страница 12: ...12 Accessory Cable PACK10 2 Accessory Cable PACK20 4 Accessory Cable PACK30 6...
Страница 13: ...13 Accessory Cable PACK40 8...
Страница 14: ...14...
Страница 28: ...28 Figure 17 Wiring the Communication Cable...
Страница 30: ...30 Figure 19 PV Wiring Step12 Close the lid and tighten the screw Figure 20...
Страница 58: ...58...