To protect against the spread of fire in living spaces where the E8KT/E10KT/E12KT is
mounted or on surfaces of a wall or structure in living spaces with a E8KT/E10KT/E12KT
on the other side, the wall or structure shall have a suitable non-combustible barrier. If the
mounting surface itself is not made of a suitable non-combustible material, a non-
combustible barrier can be placed between the E8KT/E10KT/E12KT and the surface of a
wall or structure.
If the E8KT/E10KT/E12KT is mounted at a wall or at a distance of 300mm from the wall or
the structure separating it from the habitable space, the distances to other structures or
objects must be increased. The following distances must remain free:
600 mm beside the E8KT/E10KT/E12KT; 500 mm above the E8KT/E10KT/E12KT; 600
mm before the E8KT/E10KT/E12KT.
If the distance between the E8KT/E10KT/E12KT and the ceiling or any object above
the system is less than 500mm, the ceiling or structural surface above the system must
be made of noncombustible material within a radius of 600mm around the system.
The E8KT/E10KT/E12KT must be mounted to ensure the highest point is not more than
2.2m above the ground or the platform.
Figure 8 Limited Distance of Installation to Neighboring Objects
Содержание RI-ENERGYFLOW-3P-MODULAR...
Страница 4: ...4...
Страница 12: ...12 Accessory Cable PACK10 2 Accessory Cable PACK20 4 Accessory Cable PACK30 6...
Страница 13: ...13 Accessory Cable PACK40 8...
Страница 14: ...14...
Страница 28: ...28 Figure 17 Wiring the Communication Cable...
Страница 30: ...30 Figure 19 PV Wiring Step12 Close the lid and tighten the screw Figure 20...
Страница 58: ...58...