![Rayleigh Instruments RI-ENERGYFLOW-3P-MODULAR... Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/rayleigh-instruments/ri-energyflow-3p-modular/ri-energyflow-3p-modular_user-manual_3930940047.webp)
47
Menu
Level 1
Menu
Level 2
Menu
Level 3
Menu
Level 4
Menu
Level 5
Menu Level
6
Default
Selection
Comment
Enable
Or, if enabled, to set the
export power limit.
Power
set the
export
power
limit(Range:
0~rated
power)
If Enable is selected, the user
will be prompted to enter the
power.
DRM
Enable
Disable
Disable
Only applicable in Australia
and New Zealand at this time.
Enable
EPS
Enable
Disable
Enable
Enables the Backup output
(the Load Switch needs to be
turned ON).
Enable
Remote
CTRL
Disable
Disable
Allows control via RS485
( Scada system for example).
Enable
Start
Delay
20…300Seconds
30Second
s
This is the boot delay from
when power is applied to the
inverter.
CEI SPI
Ctrl
Disable
Disable
This function is only
applicable to use via DRM for
remote control (Australian
and New Zealand markets
only).
Enable
GFCICH
K ENB
Disable
Enable
Ground fault monitoring on
the AC grid connection.
Enable
DOD
Enable
Disable
Enable
Depth of discharge. This
should always be enabled.
Disabling will result in the
battery discharging to 0%.
Enable
Generat
or
Disable
Disable
This option allows the user to
install a secondary means of
generation. For example,
wind generator or diesel
generator.
Enable
CT or
METER
CT
CT
CT option is used for
measuring the system
current.
Содержание RI-ENERGYFLOW-3P-MODULAR...
Страница 4: ...4...
Страница 12: ...12 Accessory Cable PACK10 2 Accessory Cable PACK20 4 Accessory Cable PACK30 6...
Страница 13: ...13 Accessory Cable PACK40 8...
Страница 14: ...14...
Страница 28: ...28 Figure 17 Wiring the Communication Cable...
Страница 30: ...30 Figure 19 PV Wiring Step12 Close the lid and tighten the screw Figure 20...
Страница 58: ...58...