![Rayleigh Instruments RI-ENERGYFLOW-3P-MODULAR... Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/rayleigh-instruments/ri-energyflow-3p-modular/ri-energyflow-3p-modular_user-manual_3930940010.webp)
10
1.4 Battery Safety Datasheet
1.4.1. Hazard Information
Classification of the hazardous chemical
Exempt from classification according to Australian WHS regulations.
Other hazards
This product is a Lithium Iron Phosphate Battery with certified compliance under the UN
Recommendations on Transport of Dangerous Goods, Manual of Tests and Criteria, Part III,
subsection 38.3. For the battery cell, chemical materials are stored in a hermetically sealed
metal case, designed to withstand temperatures and pressures encountered during normal
use. As a result, during normal use, there is no physical danger of ignition or explosion and
chemical danger of hazardous materials' leakage. However, if the product is exposed to afire,
added mechanical shocks, decomposed, added electric stress by misuse, the gas release
vent will be operated. The battery cell case will be breached at the extreme. Hazardous
materials may be released. Moreover, if heated strongly by the surrounding fire, acrid or
harmful fume may be emitted.
1.4.2 Safety Datasheet
For detailed information please refer to the provided battery safety datasheet.
1.5 General Precautions
DANGER
Danger to life due to high voltages of the PV array, battery and electric shock. When
exposed to sunlight, the PV array generates dangerous DC voltage which will be present
in the DC conductors and the live components of the inverter. Touching the DC
conductors or the live components can lead to lethal electric shocks. If you disconnect the
DC connectors from the system under load, an electric arc may occur leading to electric
shock and burns.
Do not touch uninsulated cable ends.
Do not touch the DC
conductors.
Do not open the inverter and battery.
Do not wipe the system with damp cloth.
Have the system installed and commissioned by qualified people with the
appropriate skills only.
Prior to performing any work on the inverter or the battery pack, disconnect
the inverter from all voltage sources as described in this document.
WARNING
Risk of chemical burns from electrolyte or toxic gases. During standard operation, no
electrolyte shall leak from the battery pack and no toxic gases shall form. Despite careful
construction, if the Battery Pack is damaged or a fault occurs, it is possible that electrolyte
may be leaked or toxic gases formed.
Do not install the system in any environment of temperature below -25
°
C
or over 60
°
C and in which humidity is over 95%.
Содержание RI-ENERGYFLOW-3P-MODULAR...
Страница 4: ...4...
Страница 12: ...12 Accessory Cable PACK10 2 Accessory Cable PACK20 4 Accessory Cable PACK30 6...
Страница 13: ...13 Accessory Cable PACK40 8...
Страница 14: ...14...
Страница 28: ...28 Figure 17 Wiring the Communication Cable...
Страница 30: ...30 Figure 19 PV Wiring Step12 Close the lid and tighten the screw Figure 20...
Страница 58: ...58...