Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-QCW300/3000
27
Table 9 ( continued )
Code
Description
Examples
STA
(cont.)
Read device status status—The status is reported as a bit-encoded
32-bit word. Undefined bits or bits defined as ―Reserved‖ can be in
any state and should be ignored. Each of the bits have the following
meaning
Bit 13
-
0 =
Compatibility Disable
-
1 =
Compatibility Enable
Bit 14
-
Reserved
Bit 15
-
Reserved
Bit 16
-
0 =
Gate Mode Disable
-
1 =
Gate Mode Enable
Bit17
-
0 =
Normal operation
-
1 =
High Pulse Energy
Bit 18
-
0 =
Hardware Emission Control Disable
-
1 =
Hardware Emission Control Disable
Bit 19
-
0 =
Normal operation
-
1 =
Power Supply Failure
Bit 20
-
Reserved
Bit 21
-
Reserved
Bit 22
-
Reserved
Bit 23
-
0 =
Normal operation
-
1 =
Duty Cycle Too High
Bit 24
-
0 =
Normal operation
-
1 =
Low Temperature
Bit 25
-
Reserved
Bit 26
-
0 =
Normal operation
-
1 =
GND Leakage
Bit 27
-
0 =
Hardware Aiming Beam Control
Disable
-
1 =
Hardware Aiming Beam Control
Enable
Bit 28
-
0 =
Normal operation
-
1 =
Aiming Beam Alarm
Bit 29
-
0 =
Normal operation
-
1 =
Critical Error
Bit 30
-
0 =
Fiber Interlock OK
-
1 =
Fiber Interlock Active
Bit 31
-
0 =
Normal operation
-
1 =
High Average Power
Sent: ―STA‖
Response: ―STA: 4100"
This
translates
to
the
following: 4100 = 0x1004,
so bits 2 and 12 are set. This
means that emission is on
and modulation is enabled.
受