Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-QCW300/3000
38
Figure 10 Control Mode Setting
Note
:
Steps of laser emission start:
Step 1: Enable emission control
(Enable emission control is performed by signal applied to the pins 7-9 of the DB-25
interface connector if hardware emission control is enabled (ELE), while it is performed by
command via RS-232 or Ethernet if hardware emission control is disabled (DLE).)
Step 2: Starts/Stops emission
(In Standalone mode, emission starts is performed by command via RS-232 or Ethernet; In
Gate/ Modulation /Wave mode, emission is performed by signal applied to the pins 17-9 of the
DB-25 interface connector)
Click
―
DEABC
‖indicate that the aiming beam
ON/OFF is controlled by buttons of ―ABF/ABN‖;
Click
―
EEABC
‖indicate that the aiming beam
ON/OFF is controlled by signal applied to the pins
7-9 of the DB-25 interface connector.
Click
―
Pulse
‖ indicate that the laser is operating in
PULSE mode; Click
―
CW
‖ indicate that the laser is
operating in CW mode.
Click
―
EGM
‖ indicate that internal pulse generator is
enabled and laser pulse sequence is performed by signal
applied to the pins 7-9 of the DB-25 interface connector.
Click
―
EMOD
‖ indicate that the internal pulse
generator is disabled and Emission start/stop is
performed by signal applied to the pins 17-9 of the
DB-25 interface connector.
Click
―
ELE
‖ indicate that hardware emission control is
enabled and Emission start/stop is performed by signal
applied to the pins 7-9 of the DB-25 interface
connector.
Click
―
EWPM
‖ indicate that laser is operating in Wave
mode.
Pulse
Pulse
Click
―
EEC
‖ indicate external power control is enabled
and power level is set via external analog voltage applied
to the pins 8-9 of the DB-25 interface connector.
Click
―
DEC
‖ indicate external power control is disabled
and power level is set via (RS-232 or Ethernet).