Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide RFL-QCW300/3000
39
c)
Parameter Setting
、
Reading and Emission Control
Figure 11 Parameter Setting and Reading and Emission Control
d)
Laser Status
Figure 12 Laser Status
Click ―
Get
‖ to get the current laser status and Click ―
ErrRST
‖ to clear all current laser errors.
This part displays the sent command and response
information corresponding to the current clicking
of the button, which is convenient for the end
users to develop their own control system.
Click
―
Clear
‖ can clear up all record in this part.
The end user can get and set laser parameters like
Power level, Pulse frequency, Pulse width through
this part. Emission start/stop can also be performed
by clicking buttons of ―Start Emission/ Stop
Emission‖
Notes:
A
)
If the laser is operating in internal
mode, emission start/stop can be performed by
clicking buttons of ―Start Emission/ Stop
Emission‖.
If the laser is operating in Gate/ Modulation
/Wave mode, ―DEL‖ means that clicking buttons
of ―Start Emission/ Stop Emission‖ is
enabled/disabled emission control, while ―EEL‖
means that clicking buttons of ―Start Emission/
Stop Emission‖ is invalid .
B
)
When Pulse repetition rate is 0, output
of laser is single pulse.
C
)
The pulse width can only be an integer
multiple of 0.02ms.
受
控
武汉锐科