Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000XZ
42
2.1.2 5.3 Emission
E
xternal
C
ontrol
E
nable
When the external control is enabled, the laser emission is determined by the MOD level state
on the pin 1 and pin 2 of xp2; If the external control emission is not enabled, the laser emission and
shutdown are determined by the light output button of the computer software, or communication
sends "EMON" to control the laser emission and send "EMOFF" to control the laser off.
5.4 Red
L
ight
C
ontrol
In the ON mode, the red light can only be turned on by sending "ABN" through the computer
software or communication, and "ABF" turns off red light. The red-light module in the laser works
by means of communication, so there is a time delay of at least 10 MS when the red light is turned on
and off;
When the red light is on, the laser cannot be set to Ready position. Only when the red light is off,
can the laser be ready (this limit can be changed, please contact Raycus Engineer).
5.5 Programming Mode
In the ON mode, when the current program number of the laser is not 0, the laser will run in the
programming mode.
Please use the computer software of Raycus to edit the wave and select the pre-operation
program number.
When
the
laser
is
in
the
emission
internal
control
mode,
press
or send EMON command
,
the laser starts to operate program; send
or press EMOFF,
the laser can stop program at any time;
When the laser is in the external control mode, the rising edge of MOD starts to operate the
program, and the falling edge of MOD can terminate the program at any time.