Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000XZ
28
a) MOD SINGLE
Figure 16 MOD Signal Circuit Diagram.
This signal is 5/24V compatible, and reverse connection is not allowed.
MOD is used to control the laser output and off when the key switch is hit ON and the laser is
working out of light external control mode.
When the key switch hits REM, and the laser is operating in outgoing light control mode, MO
D and XP1-A2 (at this time, the A2 bit outgoing light enable signal) are jointly used to control the la
ser output and off (in REM mode, outgoing light control can be controlled only by A2, to be customi
zed).
b)Passive light output indication and main power up indication
XP2's 3/4 light output indication, 15/16 is the main power has been powered on output indication,
the internal circuit diagram is as follows.