Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000XZ
23
①
INTERFACE:
this interface provides all control signals, including: RS232 communication, laser
on/off control, laser remote control mode selection, analog control, modulation signal, Interlock interface,
etc. Refer to Table 4 for the definition of control lines. This socket comes with a protective cover and a
lock. When you are not using the product, you can cover the power input socket with the protective cover
and lock it with the lock.
②
BREAKER:
the circuit breaker (air switch) on the rear panel of the laser is the main power switch
of the laser.
③
AC INPUT:
the power input socket must be matched with the plug provided by us. This socket
comes with a protective cover and a lock. When you are not using the product, you can cover the power
input socket with the protective cover and lock it with the lock.
④
FIBER WATER IN:
Output optical cable water inlet interface, this interface is connected to the
water outlet of the Normal temperature water of the water cooler and connected to the
φ
13 inner
diameter water pipe.
⑤
FIBER WATER OUT:
Output fiber optic cable out of the water interface, this interface is
connected to the output fiber optic cable inlet, connected to the φ13 inner diameter of the water.
⑥
BOTTOM WATER IN:
The lower water inlet of the laser, this interface is connected to the
outlet of the cooling water of the water cooler, connected to the water pipe of φ32 inner diameter.
⑦
FILTER:
Filter the cooling water entering the laser.
⑧
TOP WATER IN:
The upper water inlet of the laser, this interface is connected to the outlet of
the cooling water of the water cooler, connected to the water pipe of φ32 inner diameter.
⑨
TOP WATER OUT:
The upper water outlet of the laser, this interface is connected to the
cooling water return port of the water chiller and connected to the
φ
32 inner diameter water pipe. The
combination of TOP WATER OUT and TOP WATER IN is used for the outflow and return of the upper
cooling water of the laser.
⑩
BOTTOM WATER OUT:
The lower water outlet of the laser, this interface is connected to the
cooling water return port of the water chiller and connected to the
φ
32 inner diameter water pipe. The