k) Armored pipe bending radius: in non-working conditions such as transportation and storage, the
minimum bending diameter shall not be less than 15cm. When the laser is emitting, the
minimum bending diameter shall not be less than 20cm;
l) Long-term vibration, less than 2G; impact, less than 10G.
Other requirements:
a) When starting the cooling system for the first time, check the entire water system and joint for
water leakage.
b) If the laser is not used for a long time, the cooling water inside the cooling system and the laser
inside should be drained, otherwise the laser equipment will be damaged.
c) Please use compressed gas below 0.5MPa when emptying water from the device. Failure to do
so may cause permanent equipment damage to cooling system.
CAUTION:
(1) Set the water temperature of the cooling system correctly according to the ambient
temperature. Setting the water temperature too high will result in the laser not working
properly. Setting the water temperature too low will cause condensation inside the laser or the
laser output head, which will cause damage to the laser;
(2) Before turning on the laser, the cooling system must be working properly, and the water
temperature should be suitable for the temperature.
4 Using the Product
Please log in to the official website of Raycus to download the new PC software and the
PC software user manual. Website: http://www.raycuslaser.com
4.1 Front Panel
Figure 11 shows the front panel.