49.5in
1.26m
24.00in
0.61m
24.00in
0.61m
12.00in
0.30m
CLEARANCE
AREA FOR
GAME
VENTILATION!!
68in
1.73m
RECOMMENDED
CLEARANCE AREA
FOR ENTRY AND EXIT
60.00in
1.52m
97.5in
2.48m
134.27in
3.41m
KING KONG OF SKULL ISLAND VR
FOOT PRINT, SPACE AND POWER
REQUIREMENTS.
MINIMUM 10 FOOT (3 M) CEILING RECOMMENDED
AND 1 FOOT (.3 M) REAR WALL CLEARANCE REQUIRED.
RECOMMENDED
SANITARY WIPE
AND WASTE BASKET
LOCATION
12.00in
0.30m
REAR
VENTILATION
CLEARANCE
120.00in
3.05m
FLOOR TO
CEILING
HEIGHT
MONITOR BEZEL
CLEARANCE
5.69in
0.14m
CLEARANCE
WITHOUT
MONITOR BEZEL
8.42in
0.21m
122.34in
3.11m
AIR
IN
AIR
OUT
AIR
OUT
114.17in
2.90m
POWER REQUIREMENTS
120VAC : 20A
(10A per AC inlet)
230VAC : 10A
(5A per AC inlet)
DO NOT OVERLOAD AC MAINS
Provide independent 20A breaker @ 120VAC
Provide independent 10A breaker @ 230VAC
If a higher amperage AC circuit is provided, verify
total load does not exceed breaker rating.
If power issues are observed (ex: spontaneous power cycle),
split the two line cords between two different circuits.