Problem
Possible Cause
Solution
No Video
PC not turned on.
Turn PC power switch on. Ensure IEC cable tightly
plugged in. Trace cable back to source to ensure
continuity.
Video cable not secure.
Check and secure DVI or HDMI connector to
Monitor. Check and secure DVI or HDMI connector
to PC.
Cabinet was powered on
too quickly after a
manual shutdown/power
loss
Shut off cabinet via both switches at rear of cabinet.
Leave off for 30 seconds, then power back on.
Coin meter does not
click during test.
No pulse to meter.
Check wiring from meter to PCB board.
Faulty meter.
Replace coin meter.
Blown fuse(s) on PCB
Replace 12vdc 5A fuse(s) on PCB.
Exits Test Mode every 3
seconds.
Test button stuck in ON
position.
Slide or toggle button off after Test Menu appears
Improper number of
credits given when bills
are inserted.
Incorrect setting in
Pricing Adjustments.
Adjust pricing settings.
Faulty wiring.
Disconnect cabinet from AC power. Verify wires are
firmly connected to bill validator and ground wires
are properly connected. Verify no wires are frayed
or shorting to ground.
Compressor does not
turn on/low humming
noise coming from the
compressor
Compressor power cut
off while it was running.
Shut off cabinet via both switches at rear of cabinet.
Leave off for 3 minutes, then power back on.