C
HAPTER
6
76
CAN Sidekick Pro Injection for Case IH 3/4XXX Installation and Operation Manual
PRESSURE TRANSDUCER CALIBRATION
Use the Pressure Transducer Calibration screen to calibrate all pressure transducers in your sprayer control system.
1. Press the Press (pressure) icon
on the navigation bar to display the Pressure Transducer Calibration
screen.
2. Use the Rate Controller window to select the desired rate controller. Calibrate the pressure transducer at the
main tank.
3. Press the Rate Controller field to open the pop-up options window.
4. Press the rate controller name in the options window.
5. Press Update Cal to reset the pressure transducers to zero. One of two possible pop-up messages will display.
a. When the main tank is selected, the following message displays: “Before continuing with the pressure
transducer calibration, ensure that the actual boom and sparge pressures are 0 psi (0 kPa).”
b. When a direct injection tank is selected, the following message displays: “Before continuing with the
pressure transducer calibration, ensure that the injection pump pressure is 0 psi (0 kPa).”
6. Press Continue and complete the calibration.
7. Repeat this process for any other pressure transducer that requires calibration.
INJECTION PUMP CALIBRATION
The AFS Pro 700 display provides a remote closed-system calibration procedure for the injection pump in a direct
injection system.
NOTE:
Verify your settings on the Product Controller Setup screen before continuing.
Flow Alarm
Use the Flow Alarm window
to enable or disable an
alert when the pump is
running but there is no
liquid or the flow is below
the minimum.
Note: The Flow Alarm
window displays only when
a direct injection tank is
selected in the Rate
Controller window.
Press the Flow Alarm window to enable or
disable an alert when the pump is running
but there is no liquid or the flow is below
the minimum.
Press the Flow Alarm window to access the
pop-up options window.
Select either Off or On.
Vacuum Alarm
Use the Vacuum Alarm
window to enable or
disable an alert when the
vacuum is too high.
Note: The Vacuum Alarm
window displays only when
a direct injection tank is
selected in the rate
controller window.
Typical causes of high vacuum inside a
product that is too think or blockages at
the strainer or filter.
Press the Vacuum Alarm window to access
the pop-up options window.
Select either Off or On.
Setting
Description
Additional Information
Содержание Sidekick Pro
Страница 12: ...CHAPTER 2 10 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Страница 84: ...CHAPTER 7 82 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Страница 88: ...CHAPTER 8 86 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...
Страница 89: ...CHAPTER 9 System Diagrams Electrical 87 CHAPTER9SYSTEM DIAGRAMS ELECTRICAL Drawings start on next page ...
Страница 91: ...System Diagrams Electrical 89 SYSTEM DIAGRAMS FIGURE 2 Single Pump System Diagram ...
Страница 93: ...System Diagrams Electrical 91 SYSTEM DIAGRAMS PLUMBING FIGURE 4 Dual Pump Injection Plumbing ...
Страница 96: ...Index 94 CAN Sidekick Pro Injection for Case IH 3 4XXX Installation and Operation Manual ...