Maximum Vacuum
Alarm
• Clogged pump
strainer
• Clean pump strainer and check for obstructions in
injection line between the pump inlet and chemical
supply tank.
• Tubing or
plumbing size
restriction
• Verify the proper size of injection supply tubing is
used between the chemical supply tank and pump
inlet.
• Chemical too thick
• Dilute product in chemical supply tank. Some
chemicals may not be applied using a direct injection
system.
Maximum Pressure
Alarm
• Clogged or
restricted pump
outlet supply lines
• Check for restrictions or blockages in outlet supply
lines. Flush the injection system to clear clogs and
residue buildup.
• Tubing or
plumbing size
restriction
• Verify the proper size of injection outlet tubing is used
between the point of injection and pump outlet.
• Faulty PSI
transducer
• Hand valve closed
• Check hand valves are open and allow flow from the
injection pump outlet port.
• Low injection
pressure
Pressure Sensor
Alarm
• Boom pressure
transducer not
connected
• If installed, check that the boom pressure transducer
is installed and properly connected.
• Faulty boom
pressure
transducer
• Replace boom pressure transducer.
Motor/Encoder
Alarm
• No power to
pump motor
• Verify that the high current LED on the injection pump
node is lit.
• Pump motor or
encoder issue
• Check motor and encoder connections. Disconnect
the injection pump node from the pump motor and
check that the motor and encoder connections are
seated properly. If these connections appear solid,
return pump to a local Raven dealer for service.
HC Power Alarm
• Injection node not
connected to high
current power
• Verify high current breaker is not tripped.
• Verify battery connections.
Zero Speed Alarm
• Faulty cabling,
connection or
speed sensor
• Verify speed sensor and signal. Refer to the field
computer operation manual for information on testing
speed and flow cabling and troubleshooting the
speed sensor.
Low Limit Alarm
• Implement speed
or width is
insufficient to
maintain pump
rate and the pump
“low limit” rate has
become active
• The pump will maintain the programmed low limit
rate. If this rate is the desired lowest injection rate, no
action is required. If the current field operation
requires a lower rate of injection, reduce the
programmed low limit setting to allow the pump to
reduce the rate of injection. Refer to the Low Limit
Error Description
Possible Cause
Solution
Содержание Sidekick Pro ISO
Страница 1: ...Sidekick Pro ISO Installation Operation Manual P N 016 0171 509 Rev E 07 17 E29803 Copyright 2017 ...
Страница 8: ...CHAPTER 1 4 Sidekick Pro ISO Installation Operation Manual ...
Страница 16: ...CHAPTER 2 12 Sidekick Pro ISO Installation Operation Manual ...
Страница 46: ...CHAPTER 4 42 Sidekick Pro ISO Installation Operation Manual ...
Страница 70: ...CHAPTER 7 66 Sidekick Pro ISO Installation Operation Manual ...
Страница 80: ...Index 76 Sidekick Pro ISO Installation Operation Manual ...