Chapter 9
68
SCS 4000/5000 Series™ Installation & Operation Manual
25.
Console displays: “CHECK
ACCUBOOM NODE,” “CHECK
AUTOBOOM NODE,” “CHECK ROW
SENSE NODE,” or “CHECK BOOM
SENSE NODE.”
• If node is not connected to the CANbus, press DATA MENU key.
CAN menu will appear and CAN node options can be toggled ON or
OFF using the CE key. Operation can then be resumed as normal.
• Verify that node is connected to the CANbus.
• Verify that node has logic power and ground properly connected and
energized and no fuses are blown on power leads.
• Verify that CANbus cabling from the console to the node is
connected and in tact.
• Move the node and node cable to a known good CAN outlet closer to
the console (take off another node or cable if necessary). If message
for the node goes away, replace CAN cabling going to the node.
Otherwise, replace node or node cable.
26.
“Calibration Error’ encountered during
PWM auto calibration.
• Verify that the selected product node(s) are set to off. Press the
PRODUCT ON/OFF key to toggle the product off before running the
auto calibration.
• Toggle at least one section switch on before running the auto
calibration.
• Be sure that the speed cal, meter cal, valve cal, rate cal and boom
cal values are entered properly for the selected product(s).
Problem
Action
Содержание SCS 5000 Series
Страница 23: ...3 Manual No 016 0159 925 15 CAN Networking and CAN Data Menu FIGURE 6 SCS 4400 Granular Control System...
Страница 24: ...Chapter 3 16 SCS 4000 5000 Series Installation Operation Manual FIGURE 7 SCS 4600 Granular Control System...
Страница 28: ...Chapter 3 20 SCS 4000 5000 Series Installation Operation Manual...
Страница 72: ...Chapter 8 64 SCS 4000 5000 Series Installation Operation Manual...
Страница 90: ...Chapter 14 82 SCS 4000 5000 Series Installation Operation Manual...