Chapter 5
28
SCS 4000/5000 Series™ Installation & Operation Manual
Units
The default setting for the Units screen is “US Acres.”
1.
Press the CE key to cycle between SI Metric Hectares, Turf Square Feet, or US Acres.
2.
Press ENTER to accept the displayed selection and advance to the Product Control Type screen.
Product Control Type
The default setting for the product control type is “Liquid” control.
1.
Press the CE key to cycle between:
Note:
Some application types may require a specific node firmware version or an optional CANbus
control hardware. If an application type selection is not available, contact a local Raven dealer for
assistance.
LIQUID.
Application of a liquid product.
Note:
When using an optional Raven Sidekick Pro™ direct injection system with the SCS console, select
liquid for the control type setting and refer to the Valve Type section on page 29 to configure the
valve setting for the specific injection pump installed on the control system.
GRANULAR 1.
Dry or granular product application using a single encoder to meter application equipment with
a single bed.
GRANULAR 2.
Dry or granular product application using a single encoder to meter application from equipment
with a dual bed.
GRANULAR 3.
Dry or granular product application using a dual encoder configuration to meter application
from equipment with a dual bed.
SPINNER.
Select this option for RPM control of spinner speed during field operations.
NH3.
An option for anhydrous ammonia rate control operations will be available if the product node is capable
of specific rate control features. It is recommended to ensure this option is available and selected when
controlling the application of anhydrous ammonia during field operations.
NH3 BOOST PUMP.
The anhydrous pump control selection will be available if the product node is capable of
specific control features for the AccuFlow HP boost pump. Select this option to allow the operator configure
specific boost pump control features for field operations.
LIQUID 3-WAY.
When using a 3-way, or flow back, type valve with a liquid control system, select the ‘LIQUID
3-WAY” option. This control type setting allows the SCS console to properly meter the product flow applied
through the boom sections.
2.
Press ENTER to save this setting and advance to the Valve Type screen.
Содержание SCS 5000 Series
Страница 23: ...3 Manual No 016 0159 925 15 CAN Networking and CAN Data Menu FIGURE 6 SCS 4400 Granular Control System...
Страница 24: ...Chapter 3 16 SCS 4000 5000 Series Installation Operation Manual FIGURE 7 SCS 4600 Granular Control System...
Страница 28: ...Chapter 3 20 SCS 4000 5000 Series Installation Operation Manual...
Страница 72: ...Chapter 8 64 SCS 4000 5000 Series Installation Operation Manual...
Страница 90: ...Chapter 14 82 SCS 4000 5000 Series Installation Operation Manual...