Chapter 2
4
SCS 4000/5000 Series™ Installation & Operation Manual
System Components
The following sections offer a description of the system components for the various SCS consoles and control
systems.
SCS 4000/5000 Control Systems
The SCS 4000/5000 system consists of a computer-based control console, a CAN boom sense/speed node, a
speed sensor, a boom switch box or boom switches, up to five CAN product control nodes, control valve(s),
flow meter(s) or encoder(s), injection modules (if applicable), and appropriate cabling.
Note:
Due to the harsh conditions and chemicals in the field of agriculture, appropriate cabling is
required to ensure system integrity.
The SCS 4000 and 5000 control systems are designed to be used with external boom switches. In
order for the system to detect when and which booms are ON or OFF, the boom signal wires must
be connected to the correct booms.
SCS 4070 Control Systems
The SCS 4070 system consists of a computer-based control console, a CAN boom sense/AccuBoom Combo
node (if applicable), a speed sensor, up to five CAN product control nodes, control valve(s), flow meter(s) or
encoder(s), injection modules (if applicable), and appropriate cabling.
Note:
The AccuBoom Combo node will not provide automatic section control during field operations
using the SCS 4070. AccuBoom is only used to simplify cable and wiring for the built in boom
section switches when using the SCS 4070 console.
Due to the harsh conditions and chemicals in the field of agriculture, appropriate cabling is
required to ensure system integrity.
SCS 4400/4600 Control Systems
The SCS 4400/4600 system consists of a computer-based control console, a speed sensor, up to four
additional CAN product control nodes (the first product control node is hard-wired into the controller), control
valve(s), flow meter(s) or encoder(s), injection modules (if applicable), and appropriate cabling.
Note:
Due to the harsh conditions and chemicals in the field of agriculture, appropriate cabling is
required to ensure system integrity.
The SCS 4600 controller is designed to be used with external boom switches. In order for the
system to detect when and which booms are ON or OFF, the boom signal wires must be
connected to the correct booms.
The SCS 4400/4600, in conjunction with a DGPS receiver, is also capable of recording valuable application
data. This information is recorded in different formats to best fit the users needs and may be transferred via the
compact flash card to a home or office computer.
Note:
The SCS 4400 with part number 063-0172-281 and SCS 4600 with part number 063-0172-343
both feature a compact flash card slot for application data transfer to a home or office computer.
The data logging feature will only be used when connecting to an optional external console for
logging or mapping applications.
Содержание SCS 5000 Series
Страница 23: ...3 Manual No 016 0159 925 15 CAN Networking and CAN Data Menu FIGURE 6 SCS 4400 Granular Control System...
Страница 24: ...Chapter 3 16 SCS 4000 5000 Series Installation Operation Manual FIGURE 7 SCS 4600 Granular Control System...
Страница 28: ...Chapter 3 20 SCS 4000 5000 Series Installation Operation Manual...
Страница 72: ...Chapter 8 64 SCS 4000 5000 Series Installation Operation Manual...
Страница 90: ...Chapter 14 82 SCS 4000 5000 Series Installation Operation Manual...