CHAPTER
6
Manual No. 016-0171-496 Rev. C
43
Chapter 6
AccuFlow HP™
Calibration and
Operation
This chapter contains information on calculating or adjusting calibration values for the AccuFlow HP™ system.
These values must be programmed on the console providing product control. Refer to the console Installation
and Operation manual for detailed programming instructions.
Note:
Before the AccuFlow system and connected console may be used to control anhydrous ammonia
application, the following calibration values must be programmed on the Raven product control
console:
•
Boom Cal
•
Speed Cal
•
Meter Cal
•
Valve Cal
•
Rate Cal
Refer to the Raven control console Installation and Operation manual for instructions on installing
a Raven CANbus system.
The high performance AccuFlow system requires a CANbus system with two product control capability.
•
Product 1 - NH
3
Rate Control
•
Product 2 - Boost Pump Control
Note:
A single product control node and product cables must be added to a 4400 console or field
computer with Switch Pro to control the boost pump.
CAUTION
To avoid damage to boost pump seals, do not
run the boost pump dry. Be sure to shutdown
the boost pump when no anhydrous ammonia
is flowing through the pump or when the nurse
tank is empty.
Содержание AccuFlow
Страница 1: ...AccuFlow HP Patent Pending AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 14: ...Chapter 2 10 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 28: ...Chapter 3 24 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 34: ...Chapter 4 30 AccuFlow and AccuFlow HP Installation Operation Manual FIGURE 2 Pressure vs Temperature Chart ...
Страница 68: ...Chapter 8 64 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 86: ...Index 82 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 89: ......