![Raven AccuFlow Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/raven/accuflow/accuflow_installation-and-operation-manual_788789031.webp)
4
Manual No. 016-0171-496 Rev. C
27
Standard AccuFlow™ Calibration and Operation
For Example:
(English Units) Given a target application rate of 150 lbs(N)/acre at an average of 5.5 mph and a calculated
implement width of 480 inches, the required capacity is:
150 x 5.5 x 480 = 66.6 lbs(N)/min
5940
..........................
(EQ 7)
(SI Units) Given a target application rate of 68 kg(N)/ha at an average of 10 km/hr and a calculated
implement width of 1220 centimeters, the required capacity is:
68 x 10 x 1220 = 13.8 kg(N)/min
60,000
........................
(EQ 8)
The maximum capacity of the 30 GPM AccuFlow system is 126 lbs(N)/min [57 kg(N)/min]. Contact a local
Raven dealer if the maximum rate is exceeded.
System Capacity Chart
The following figure illustrates the capacity of the AccuFlow™ system in various configurations. Refer to this
chart as part of the calculation for required capacity and when troubleshooting the AccuFlow system.
FIGURE 1.
System Capacity Chart
Adjusting the Valve Cal
Refer to the Raven console
Installation and Operation Manual
for instructions on calculating or adjusting the
valve cal.
Note:
The valve cal may need to be adjusted to obtain desired results, particularly in applications using
low flow rates.
Содержание AccuFlow
Страница 1: ...AccuFlow HP Patent Pending AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 14: ...Chapter 2 10 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 28: ...Chapter 3 24 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 34: ...Chapter 4 30 AccuFlow and AccuFlow HP Installation Operation Manual FIGURE 2 Pressure vs Temperature Chart ...
Страница 68: ...Chapter 8 64 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 86: ...Index 82 AccuFlow and AccuFlow HP Installation Operation Manual ...
Страница 89: ......