Use and maintenance manual R 1000 Pro
Pag.49
Rev.0 18/04/2023
EN
3
4
Checking the seals
📌
This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre.
When thoroughly cleaning the stove, the authorised technician must check that the gaskets of
- port
- hatches
are intact. If not, they will have to be replaced.
Smoke conduit cleaning
📌
This operation must be carried out by a Ravelli Assistance Centre. Schedule this type of cleaning with the Ravelli Assistance
Centre.
The stove is equipped with some hatches for cleaning the internal smoke ducts.
To clean the smoke ducts, proceed as described below:
Step
Action
1
Extract the fireplace
2
Open the hatch A
3
Remove vermiculites (see previous paragraph)
4
Clean the ash from all the hatches, eventually use a brush or similar and reassemble everything.
Note: the hatches are equipped with gaskets, therefore, before reassembling them, make sure that the gaskets are not
worn.
Note: The operation must be carried out when the stove is cold, using an ash vacuum cleaner.
A
Hatch
Gasket
Hatch
Hatch