Use and maintenance manual R 1000 Pro
Pag.26
Rev.0 18/04/2023
EN
Minimum safety distances
Minimum internal distances
The installation niche must be made of non-flammable materi-
al. The minimum distances between the fireplace and walls are
shown in the drawing:
Minimum internal distances
A) Upper
200 mm
B) Rear and
lateral
50 mm
Minimum external distances
Flammable objects and walls can not be placed within the high-
lighted area in the drawing:
Minimum external distances
C) Floor
150 mm
D) Front
800 mm
E) Lateral
150 mm
A
C
B
D
E
E
Air grills
To avoid overheating of the unit, air recirculation with one or more openings must be created in the upper and lower part of the
cladding.
Observe the minimum dimensions shown in the drawing:
Air grills
F) Upper
Hot air outlet
500 cm
2
G) Lower
Cold air inlet
500 cm
2
H) Laterals
(in case of installation
on a support)
2 x 250 cm
2
F
F
G
H