3.1
Tractor requirements
Before installing the machine control unit, ensure that your tractor meets the following requirements:
•
A minimum voltage of
11 V
must
always
be guaranteed, even if multiple loads are connected
simultaneously (e.g., air conditioning system, lights)
•
The PTO speed must be
540 rpm
as a minimum requirement and must be complied with (basic
requirement for a correct working width).
On tractors without load-switchable transmission, the forward speed must be selected by
using the correct gear ratio in such a way that it corresponds to a PTO speed of
540 rpm
.
•
A 7-pin socket (DIN 9684-1/ISO 11786). Via this socket, the control unit receives the pulse for the
current forward speed.
The 7-pin socket for the tractor and the forward speed sensor can be obtained as an
expansion kit (option), see chapter
3.2
Connections, sockets
3.2.1
Power supply
The tractor supplies the machine control with power via the 3-pin connector (DIN 9680/ISO 12369).
Fig. 9: PIN assignment of power socket
[1]
PIN 1: is not required
[2]
PIN 2: (15/30): +12 V
[3]
PIN 3: (31): Ground
3. Attachment and installation
24
5902662
QUANTRON-A AXIS/MDS