6
Alarm messages and possible causes
6.1
Meaning of the alarm messages
Various alarm messages can be displayed on the QUANTRON-A control unit display.
No. Message in display
Meaning and possible cause
1
Fault in dosing system, stop !
The motor of the metering system cannot reach
the specified target value:
•
Blockage
•
No position feedback
2
Max. outlet reached! Speed or application rate
too high
Metering slide alarm
•
The maximum metering opening is
reached.
•
The set application rate (+/- quantity)
exceeds the maximum metering opening.
3
Flow factor is outside limits
The flow factor must lie within a range between
0.40 and 1.90.
•
The newly calculated or entered flow
factor is outside this range
4
Hopper left empty!
The filling level sensor on the left reports
“empty.”
•
The left hopper is empty.
5
Hopper right empty!
The filling level sensor on the right reports
“empty.”
•
The right hopper is empty.
7
Data will be deleted!
Delete = START Cancel = ESC
Safety alarm to prevent the unintentional
deletion of data
8
Min. quantity (150 kg) not achieved, old factor
valid
Flow factor calculation not possible
•
The application rate is too low to calculate
the new flow factor when the remaining
quantity is weighed.
•
The old flow factor is retained.
6. Alarm messages and possible causes
102
5902662
QUANTRON-A AXIS/MDS