Spreading operation using the QUANTRON-A control unit
5
92
5.2
Working with sections (AXIS only)
5.2.1
Spreading with reduced section widths
Spreading can be done with section widths on one or both sides, in order to adapt
the overall spreading width to the field requirements. Each spreading side can be
adjusted in four steps (VariSpread 8) or gradually (VariSpread pro).
See
2.1: Overview of the supported versions, page 5
Press the
L%/R%
key until the desired function keys are displayed.
Figure 5.1:
Operating screen for spreading operation with section widths
[1] Right section width will spread to the entire half
[2] Function keys for increasing or reducing the spreading width on the right
[3] Function keys for increasing or reducing the spreading width on the left
[4] Left section width is reduced to two steps
1.
Press the
Reduce left spreading width
or
Reduce right spreading width
function key.
The section width of the spreading side is reduced by one step.
2.
Press the
Increase left spreading width
or
Increase right spreading width
function key.
The section width of the spreading side is increased by one step.
NOTICE
Each section width can be reduced or increased in four steps or gradually.
NOTICE
The section widths are not scaled proportionally. You can set the spreading
widths with the VariSpread spreading width wizard.
See
4.6.12: Calculate VariSpread, page 57
.
2
3
4
1
Содержание QUANTRON-A
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 17: ...Layout and function 11 2 Figure 2 5 Control unit display MDS operating screen example 3 11...
Страница 26: ...Layout and function 2 20...
Страница 96: ...Operation QUANTRON A 4 90...
Страница 118: ...Index D...
Страница 120: ......