Alarm messages and possible causes
105
6
32 Externally controlled parts
may move. Risk of injury
through squeezing and
shearing!
Direct ALL persons out of the
danger zone. Read the
instruction manual.
Parts may move unexpectedly when the
machine control unit is switched on.
Follow the displayed instructions only if
all risks have been eliminated.
34 The spreader ist set to re-
duced disc speed. The idle
measurement cannot be
started; Confirm this alarm to
set the machine back to nor-
mal spreading mode.
The flow factor must lie within a range of
0.50 - 1.80
.
The newly calculated or entered flow
factor is outside the range.
36 Weighing quantity impossi-
ble. Machine must stop.
Alarm message during weighing.
The
Weigh quantity
function can only
be carried out when the machine is at a
standstill in a horizontal position.
45 Error M-EMC sensors.
EMC control deactivated!
The sensor is not sending any signals
Cable break
Defective sensor
46 Spreading speed error.
Observe spreading speed
of 3900..650 rpm!
The PTO speed is outside the range for the
M EMC function.
47 Left dosing error, hopper
empty, outflow blocked!
Hopper empty
Outlet blocked
48 Right dosing error, hopper
empty, outflow blocked!
Hopper empty
Outlet blocked
49 Idle measurement implausi-
ble. EMC control deactivated!
Defective sensor
Defective transmission
50 Idle measurement impossi-
ble. EMC control deactivated!
PTO speed permanently unstable
51 Hopper empty.
The kg level sensor signals “empty”. The
entered value is not reached.
52 Error at hopper cover
Actuator overloaded
53 Defect at hopper cover
Defective TELIMAT actuator
54 TELIMAT Position ändern!
The TEILMAT position does not correspond
to the state notified by GPS Control
75 This disc type requires a
modification on theTELIMAT
device. Please follow
themounting instructions!
S1 spreading disc is installed and the ma-
chine is equipped with TELIMAT. Spreading
errors possible during border spreading.
This spreading disc type requires the
conversion of the TELIMAT device.
No. Message on display
Meaning
Possible cause
Содержание QUANTRON-A
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 17: ...Layout and function 11 2 Figure 2 5 Control unit display MDS operating screen example 3 11...
Страница 26: ...Layout and function 2 20...
Страница 96: ...Operation QUANTRON A 4 90...
Страница 118: ...Index D...
Страница 120: ......