Operation QUANTRON-A
4
64
MAN scale: manual operation with scale value
1.
Open the menu
Machine settings > AUTO/MAN mode
.
2.
Highlight the
MAN scale
menu entry.
The display shows the
Metering slider opening
menu.
3.
Enter the scale value for the metering slider opening.
4.
Press the
enter key
.
See
4.14.2: Input of values using the cursor keys, page 88
The operating mode setting is saved.
In
MAN scale
operating mode, you can manually change the metering slider
opening during spreading.
Precondition:
The metering sliders are open (activation with the
Start/Stop
key).
On the
MAN scale
operating screen, the symbols for the section widths are
filled in red.
Figure 4.19:
Man scale operating screen
[1] Display of the current metering slider scale position
5.
For changes to the metering slider opening, press
F2
or
F3
.
F2
:
MAN+
to increase the metering slider opening
F3
:
MAN-
to reduce the metering slider opening.
NOTICE
In order to achieve optimum spreading results even in manual mode, we recom-
mend using the values for the metering slider opening and the forward speed
provided in the fertiliser chart.