Faults and possible causes
10
104
Blockage of metering outlets
through: lumps of spreading ma-
terial, damp fertiliser, miscellane-
ous impurities (leaves, straw,
sack residues)
Clear blockages. Proceed as follows:
1. Park tractor, remove ignition key.
2. Open metering slider.
3. Place catch basin underneath.
4. Clean outlet
from below
with a wooden pole, or clean the
adjusting lever and push through the metering opening.
5. Remove any foreign objects in the hopper.
6. Close metering slider.
The spreading disc does not turn
or stops suddenly after being
turned on
If you are using a universal drive shaft with shear pin protec-
tion:
Check the shear pin, and replace shear pin if necessary
(see the universal drive shaft manufacturer's manual).
Fault
Possible cause/action