4.
Control panel harness
⚫
Remove wiring harness from the panel,
rectifier bridge and frequency converter.
Check the insulation of the wire for obvious
damage. If it is damaged, replace the
harness.
⚫
Check the conductivity of each wire with an
ohmmeter to confirm that each wire is
conducted. If the resistance is infinite,
replace the harness.
⚫
Note: Use clamps when removing and
attaching harnesses, and use appropriate
force to avoid damage to wires and wire
connectors.
5.
Breaker Protector
⚫
When the electronic equipment connected to
the generator is running, if the current
exceeds the rated current, the DC switch
automatically turns to the "OFF" position.
When operating the generator again, press
the DC switch to the "ON" position.
⚫
Check the continuity between the DC circuit
breaker terminals with a multimeter. The
circuit breaker button should be turned on
when pressed.
6.
DC socket
⚫
Generally there is no problem with DC
socket. If there is no DC output, generally it’s
mainly to check the conduction, secondly to
check if there is any breakage or not.
7.
Duplex Socket
⚫
Generally there is no problem with DC
socket. If there is no DC output, generally it’s
mainly to check the conduction, secondly to
check if there is any breakage or not.
Digital
multi-meter
Through red
Needle
test
Blue
Blue
Red
Black
Tested
by
black
needle
Blue
Non-con
duction
Non-con
duction
Condu
ction
Blue
Non-condu
ction
Conducti
on
Condu
ction
Red
Conduction
Conducti
on
Condu
ction
Blac
k
Non-condu
ction
Non-con
duction
Non-con
duction
Rectifier bridge
Multimeter
Содержание R1000I