3-2 Fault Diagnosis
The condition of indicator light flashing when the inverter is alarming (error 2%):
The green indicator on indicates that it is working normally and there is output;
The green indicator on and red indicator flashing on indicates that it is overloaded and there is output;
Green light is off, and the red light flashes 1 time, and then flashes 1 time again after an interval of 3s,
which indicates that the voltage at the front end of the bus is too low, and there is no output;
Green light is off, and red light flashes 2 times, and then flashes 2 times again after an interval of 3s,
which indicates that the engine speed is too low, and there is no output;
Green indicator is off, red indicator flashes 3 times, and then flashes 3 times once again after an
interval of 3s, which indicates that inverter temperature is height and the has no output;
Green light is off, red light flashes 5 times, and then flashes 5 times again after an interval of 3s, which
indicates that the voltage at the front end of the bus is too high, and there is no output;
Green light is off, red light flashes 6 times, and then flashes 6 times again after an interval of 3s, which
indicates after the overload is disconnected,
Inability to start
Ignition system
Testing spark plug
Fuel system
Check the ignition
coil
Carburetor
Oil Line Test
Oil protection test
Valve Train
Cylinder
pressure test
Valve Clearance Test
Operating
abnormal
sound
Unstable
speed
Crank and connecting
rod mechanism
Difficult starting
Starting and
flameout
Starting
rebound
Abnormal
sound inside
the box
Abnormal
sound outside
the box
Hunting
Speed too low
Speed too high
Intake system
Exhaust
system
Muffler test