Part II Maintenance
2-1 Service List
Good maintenance and service is the best guarantee for safe, economical and zero-failure operation.
It also contributes to environmental protection.
The exhaust gas of the generator contains toxic carbon monoxide, please stop the
gasoline engine for maintenance. If you have to implement the maintenance when
generator running, please make sure the working area is draughty.
Regular maintenance and service can ensure that the generator is working in good condition. The
maintenance schedule is as follows:
Regular maintenance schedule
Every
time of
use
20h or in the first
month of initial
use (3)
50h or
every 3
months (3)
100h or
every 6
months (3)
300h or
every
year (3)
Engine oil
Check oil level
○
Replace
○
○
Air filter
Inspection
○
Clear
○(1)
Fuel cup
Clear
○
Spark plug
Clear
○
Replace
Valve clearance Readjustment
○(2)
Cylinder head
Cleaning
Every 300 hours (2)
Fuel tank and
filter
Cleaning
Every 2 years (2)
Fuel hose
Replace
Every 2 years (2)
(1) Please increase the maintenance frequency if generator used in dusty area.
(2) These items should be maintained by franchised dealer.
(3) These items should be maintained in proper time interval as requested to insure
generator’s life