![Rational iCombi Pro XS 6-2/3 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/rational/icombi-pro-xs-6-2-3/icombi-pro-xs-6-2-3_operating-instructions-manual_3816265073.webp)
13 | Settings
Operating instructions
73 / 112
>>
The setting is immediately adopted.
13.6.7
Extra time in manual programs in the iProductionManager
Here you can set whether the cooking time should be extended in manual programs in the iProductionManager of
the cooking cabinet door is opened during the cooking time and the measured energy loss is so high that the
cooking result cannot be achieved with the selected setting.
1. To activate the function, press the button:
Extra time in manual programs in the iProductionManager ON
13.6.8
Climate retention time
Here you can set how long the climate in the cooking space should be maintained, if you do not prepare dishes
with the iProductionManager.
1. Press the button
Climate retention time
2. Select the desired value on the scale.
>>
The retention time is immediately adjusted.
NOTICE
Save energy with a shorter retention time.
13.6.9
iProductionManager 3D
Here you can set that you want to load onto the racks with two metal sheets in the iProductionManager. Each
metal sheet is monitored separately. Please note that no more than 12 racks can be displayed.
1. To activate the function, press the button:
ON
>>
The setting is immediately adopted.
13.7
Cleaning
1. Press the button
2. Press the button
Cleaning
13.7.1
Forced cleaning
Here you can set how long you would like to pass before you receive a reminder to clean the unit. You cannot
work with the unit again until the cleaning has been performed. This means that you can ensure that cleaning and
hygiene regulations are observed when the unit is in shift operation. Click here for more information: Forced
cleaning [