13 | Inspiration and help
54 / 64
Operating instructions
Error report
Cause
Cooking possible
Data communication failed
Service (E) 34.64
Data communication failed
The internal data communication is faulty.
Yes
Service (E) 34.400
Data communication failed
The internal data communication is faulty.
Yes
Service (E) 41
The steam injection nozzle or the steam
injection pipe has scale.
The
steam injection
is not
available.
Service (E) 50
Initialise timer
The real time clock on the CPU is not
initialised. Set the date and time.
Yes
Service (E) 51
Battery failed
The battery is defective.
Yes
Service (E) 52.1
Cabinet light failed
The cooking cabinet lighting is not
working correctly.
Yes
Service (E) 52.2
Cabinet light failed
The cooking cabinet lighting is not
working correctly.
Yes
Service (E) 72
The safety temperature limiter
has initialised
The activation temperature of a
temperature probe has been exceeded.
No
13.3.8
Error messages when operating the UltraVent
The following error messages may appear when your operate your unit with an UltraVent. For all error messages,
please contact your RATIONAL Service Partner [
50]. Always have the serial number of your unit ready.
Error report
Cause
Service (E) 35
The unit hood is not recognised.
Service (E) 35.1
The unit hood motor is defective.
Service (E) 35.2
The unit hood filter is not recognised.
Service (E) 35.3
The thermal element control is faulty.
Service (E) 35.4
The motor protection thermal element is faulty.
Service (E) 35.5
The UltraVent filter is dirty.
Service (E) 35.6
The UltraVent filter is dirty.
Service (E) 35.7
The UltraVent filter is not inserted.
Содержание iCombi Classic Series